Nuclear track detectors evaluation for radon activity concentration measurements

The Ionizing Radiation Metrology Laboratory (LMRI) from IFIN-HH has evaluated nuclear track detector responses to radon (<sup>222</sup>Rn). In order to perform the evaluation, a radon source was prepared using the standard system for the radon extraction from a solid <sup>226</sup>Ra Pylon source with certified activity traceable to the NIST, USA. The solid state nuclear track detectors (SSNTDs) type TASTRACK PADC from TASL were exposed to radon in the radon chamber at the LMRI (1 m<sup>3</sup> volume) together with the AlphaGuard DF2000 (AG) radon reference monitor. After exposure, the SSNTDs were placed and processed in a Clifton Digital bath with NaOH solution. After etching, an optical system (TASLImage) was used to determine the integrated exposure. The present analysis was made in order to develop a working procedure for the calibration of an SSNTD in a radon chamber. LMRI aims to extend the calibration services for customers with the nuclear track detectors calibration. The results for the radon activity concentration in air obtained with the SSNTDs were in good agreement (±10 %) with the values registered by the reference radon monitor.

Authors

Institutions

Publication Details

Journal
Applied Radiation and Isotopes
Published
2026-01-09
DOI
https://doi.org/10.1016/j.apradiso.2026.112421
Primary Topic
Radioactivity and Radon Measurements
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Nuclear track detectors evaluation for radon activity concentration measurements

Ioana Lalau, Mihail-Razvan Ioan, Mastaneh Zadehrafi, Aurelian Luca
Applied Radiation and Isotopes
Radioactivity and Radon Measurements
article

Nuclear track detectors evaluation for radon activity concentration measurements

Ioana Lalau, Mihail-Razvan Ioan, Mastaneh Zadehrafi, Aurelian Luca
article en

Abstract

The Ionizing Radiation Metrology Laboratory (LMRI) from IFIN-HH has evaluated nuclear track detector responses to radon (<sup>222</sup>Rn). In order to perform the evaluation, a radon source was prepared using the standard system for the radon extraction from a solid <sup>226</sup>Ra Pylon source with certified activity traceable to the NIST, USA. The solid state nuclear track detectors (SSNTDs) type TASTRACK PADC from TASL were exposed to radon in the radon chamber at the LMRI (1 m<sup>3</sup> volume) together with the AlphaGuard DF2000 (AG) radon reference monitor. After exposure, the SSNTDs were placed and processed in a Clifton Digital bath with NaOH solution. After etching, an optical system (TASLImage) was used to determine the integrated exposure. The present analysis was made in order to develop a working procedure for the calibration of an SSNTD in a radon chamber. LMRI aims to extend the calibration services for customers with the nuclear track detectors calibration. The results for the radon activity concentration in air obtained with the SSNTDs were in good agreement (±10 %) with the values registered by the reference radon monitor.

Applied Radiation and IsotopesVol. 229
Horia Hulubei National Institute for R and D in Physics and Nuclear Engineering (RO)
Openalex Percentile: Top 93%
Radioactivity and Radon Measurements
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Nuclear track detectors evaluation for radon activity concentration measurements — Ioana Lalau, Mihail-Razvan Ioan, et al. · Applied Radiation and Isotopes (2026) | TGRS Research Map | TGRS