Performance of Axially Compressed Reinforced Concrete Walls with Openings Strengthened Using Glass Fiber and Welded Wire Mesh Reinforced Engineered Cementitious Composites

Abstract This study explores the structural behavior of axially loaded reinforced concrete (RC) walls with openings strengthened using glass fiber (GF) or welded wire mesh (WWM) reinforced engineered cementitious composites (ECC). Eleven instrumented specimens were constructed, prepared, and tested up to collapse. The primary factors investigated included opening size and shape, wall slenderness ratio, and the type of reinforcement employed for strengthening. Both square and circular openings were introduced, while the sizes were 0.25 and 0.20 of the wall’s width. Two wall heights were designed leading to slenderness ratios of 7.5 and 9.4. Both GF and WWM were employed to reinforce the ECC layer for strengthening the walls around the openings. Finite-element modeling (FEM) was conducted using Abaqus to simulate the load–displacement response, employing validated material models for concrete, reinforcements, and ECC layers. Experimental and numerical results confirmed that walls with ECC strengthening demonstrated significant enhancements in ultimate load capacity and stiffness compared to unstrengthened samples. Among the strengthening techniques, WWM embedded in the ECC layer yielded the highest ultimate load and energy absorption. A parametric study was performed to assess the influence of ECC layer thickness, indicating that increased thickness improved load capacity, with diminishing returns observed beyond 25 mm. The relationship between ECC thickness and ultimate load was represented by a third-degree polynomial equation with high accuracy. This study features the potential of ECC with embedded WWM as an efficient strengthening solution for reinforced concrete walls with openings.

Authors

Institutions

Publication Details

Journal
International Journal of Concrete Structures and Materials
Published
2026-01-09
DOI
https://doi.org/10.1186/s40069-025-00873-2
Citations
1
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
25.98
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance of Axially Compressed Reinforced Concrete Walls with Openings Strengthened Using Glass Fiber and Welded Wire Mesh Reinforced Engineered Cementitious Composites

Ramy I. Shahin, Aref A. Abadel, Ahmad Saad, Ahmed Hamoda et al.
1 citations
International Journal of Concrete Structures and Materials
Structural Behavior of Reinforced Concrete
25.98
article

Performance of Axially Compressed Reinforced Concrete Walls with Openings Strengthened Using Glass Fiber and Welded Wire Mesh Reinforced Engineered Cementitious Composites

Ramy I. Shahin, Aref A. Abadel, Ahmad Saad, Ahmed Hamoda, Mizan Ahmed, Abedulgader Baktheer
article en
1 citations

Abstract

Abstract This study explores the structural behavior of axially loaded reinforced concrete (RC) walls with openings strengthened using glass fiber (GF) or welded wire mesh (WWM) reinforced engineered cementitious composites (ECC). Eleven instrumented specimens were constructed, prepared, and tested up to collapse. The primary factors investigated included opening size and shape, wall slenderness ratio, and the type of reinforcement employed for strengthening. Both square and circular openings were introduced, while the sizes were 0.25 and 0.20 of the wall’s width. Two wall heights were designed leading to slenderness ratios of 7.5 and 9.4. Both GF and WWM were employed to reinforce the ECC layer for strengthening the walls around the openings. Finite-element modeling (FEM) was conducted using Abaqus to simulate the load–displacement response, employing validated material models for concrete, reinforcements, and ECC layers. Experimental and numerical results confirmed that walls with ECC strengthening demonstrated significant enhancements in ultimate load capacity and stiffness compared to unstrengthened samples. Among the strengthening techniques, WWM embedded in the ECC layer yielded the highest ultimate load and energy absorption. A parametric study was performed to assess the influence of ECC layer thickness, indicating that increased thickness improved load capacity, with diminishing returns observed beyond 25 mm. The relationship between ECC thickness and ultimate load was represented by a third-degree polynomial equation with high accuracy. This study features the potential of ECC with embedded WWM as an efficient strengthening solution for reinforced concrete walls with openings.

International Journal of Concrete Structures and MaterialsVol. 20(1)
Leibniz University Hannover (DE), Kafrelsheikh University (EG), Curtin University (AU), King Saud University (SA), Higher Institute of Engineering (EG)
Sustainable cities and communities
Openalex Percentile: Top 2%
Structural Behavior of Reinforced Concrete
25.98
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.