Standardization of Mechanical Experiments with Biomaterials

Abstract The ability to determine the effective modulus of elasticity of human cancellous bone tissue is clinically significant in many areas of biomedicine, including bone quality assessment, orthopedic treatment planning, and implant design. The modulus of elasticity can be determined from uniaxial compression experiments. Many research teams conduct compression tests on cancellous bone specimens, however, there is no laboratory testing standard for conducting such experiments. This makes it difficult to compare, analyze, and use the constants obtained. The study of bovine cancellous bone specimens was conducted in two laboratories: at Saratov University and Ishlinsky Institute for Problems in Mechanics RAS. Rectangular parallelepiped specimens for the experiments were prepared from lumbar vertebrae and knee joints. The relative height of the specimens is at least 5 units. The effective modulus of elasticity is calculated using the rod theory, which assumes that the specimen is in a state of uniaxial stress. The effect of deformation rate and preliminary cycling on the measured effective modulus of elasticity has been evaluated. It has been shown that two to three cycles of loading and unloading with preliminary cycling up to a deformation of 0.5% are sufficient to stabilize the stiffness of the specimen and the effective modulus. It has been found that in the compression rate range from 0.0009 to 0.009 s –1 , the experimental results do not depend on the deformation rate. The conclusions obtained are valid for “long” cancellous bone specimens with a relative height of at least 5 units. This study represents another step towards the development of a laboratory testing standard for uniaxial compression of cancellous bone specimens to determine their effective modulus of elasticity and other mechanical properties.

Authors

Institutions

Publication Details

Journal
Mechanics of Solids
Published
2026-01-09
DOI
https://doi.org/10.1134/s0025654425604525
Primary Topic
Bone health and osteoporosis research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Standardization of Mechanical Experiments with Biomaterials

L. Yu. Kossovich, I. F. Parshina, D. S. Lisovenko, A. V. Dol’ et al.
Mechanics of Solids
Bone health and osteoporosis research
article

Standardization of Mechanical Experiments with Biomaterials

L. Yu. Kossovich, I. F. Parshina, D. S. Lisovenko, A. V. Dol’, A. V. Chentsov, D. V. Ivanov
article en

Abstract

Abstract The ability to determine the effective modulus of elasticity of human cancellous bone tissue is clinically significant in many areas of biomedicine, including bone quality assessment, orthopedic treatment planning, and implant design. The modulus of elasticity can be determined from uniaxial compression experiments. Many research teams conduct compression tests on cancellous bone specimens, however, there is no laboratory testing standard for conducting such experiments. This makes it difficult to compare, analyze, and use the constants obtained. The study of bovine cancellous bone specimens was conducted in two laboratories: at Saratov University and Ishlinsky Institute for Problems in Mechanics RAS. Rectangular parallelepiped specimens for the experiments were prepared from lumbar vertebrae and knee joints. The relative height of the specimens is at least 5 units. The effective modulus of elasticity is calculated using the rod theory, which assumes that the specimen is in a state of uniaxial stress. The effect of deformation rate and preliminary cycling on the measured effective modulus of elasticity has been evaluated. It has been shown that two to three cycles of loading and unloading with preliminary cycling up to a deformation of 0.5% are sufficient to stabilize the stiffness of the specimen and the effective modulus. It has been found that in the compression rate range from 0.0009 to 0.009 s –1 , the experimental results do not depend on the deformation rate. The conclusions obtained are valid for “long” cancellous bone specimens with a relative height of at least 5 units. This study represents another step towards the development of a laboratory testing standard for uniaxial compression of cancellous bone specimens to determine their effective modulus of elasticity and other mechanical properties.

Mechanics of Solids
Saratov State University (RU), Institute for Problems in Mechanics (RU)
Openalex Percentile: Top 93%
Bone health and osteoporosis research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.