Is Ultrahigh Dose Rate Critical for the Effectiveness of Microbeam Radiation Therapy in a Broad-Beam Combined Treatment?

Purpose The superior therapeutic index of preclinical synchrotron microbeam radiation therapy (MRT) over conventional broad-beam (BB) radiation therapy (RT) has been clearly established. Published data demonstrate that a combination of 1 MRT session with 2 consecutive daily BB-RT sessions effectively controls the primary tumor and triggers an antitumor immune response. Here, we aimed to establish whether an ultrahigh dose rate of MRT, available exclusively on the synchrotron, is essential for effective treatment of murine triple-negative mammary carcinoma.Methods And Materials The in vitro response of mammary tumor cells was investigated using a clonogenic survival assay at different MRT dose rates (∼1000, 100, or 10 Gy/s). The in vivo tumor responses at the same dose rates, with an MRT/BB/BB treatment schedule, were evaluated by measuring tumor volume and the induced immune response. Animal survival and normal skin reactions were also assessed.Results Clonogenic survival decreased with decreasing MRT dose rate, with most cell sparing at the highest dose rate (1000 Gy/s), indicating that lower dose rates could be more effective against tumors. However, no significant differences in in vivo tumor growth delay were observed in response to dose-rate variations. Decreased infiltration of irradiated tumors with leucocytes and their subpopulations was observed at the lower dose rates, including decreased expression of immune checkpoints PD-1/PD-L1 and prognostic marker CD103, which could impact the overall tumor response in vivo. The higher dose rates were associated with increased antitumor immunity. Early euthanasia of mice, as dictated by ethical endpoints, prevented long-term observation of differences in animal survival. Skin toxicity in the vicinity of irradiated tumors was mild and developed later at the highest MRT dose rate. Overall, MRT at 10 to 1000 Gy/s was tolerated similarly, despite dramatic changes in the dose rate.Conclusions These findings are promising for the clinical translation of MRT in combination with conventional RT, using emerging compact x-ray MRT sources with dose rates lower than those delivered by synchrotron sources.

Authors

Institutions

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2026-01-09
DOI
https://doi.org/10.48620/93718
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Is Ultrahigh Dose Rate Critical for the Effectiveness of Microbeam Radiation Therapy in a Broad-Beam Combined Treatment?

Valentin Djonov, Bettina de Breuyn Dietler, Verdiana Trappetti, Kellie A. Mouchemore et al.
Open Access CRIS of the University of Bern
Radiation Therapy and Dosimetry
article

Is Ultrahigh Dose Rate Critical for the Effectiveness of Microbeam Radiation Therapy in a Broad-Beam Combined Treatment?

Valentin Djonov, Bettina de Breuyn Dietler, Verdiana Trappetti, Kellie A. Mouchemore, Vincent de Rover, Helen B. Forrester, Mitzi Klein, Alice H. Sprung, Elette Engels, Robin L Anderson, Matthew Cameron, Olga A Martin, Michael L F Lerch, Kirsty Brunt, Micah J Barnes, Anatoly B Rosenfeld
article en

Abstract

Purpose The superior therapeutic index of preclinical synchrotron microbeam radiation therapy (MRT) over conventional broad-beam (BB) radiation therapy (RT) has been clearly established. Published data demonstrate that a combination of 1 MRT session with 2 consecutive daily BB-RT sessions effectively controls the primary tumor and triggers an antitumor immune response. Here, we aimed to establish whether an ultrahigh dose rate of MRT, available exclusively on the synchrotron, is essential for effective treatment of murine triple-negative mammary carcinoma.Methods And Materials The in vitro response of mammary tumor cells was investigated using a clonogenic survival assay at different MRT dose rates (∼1000, 100, or 10 Gy/s). The in vivo tumor responses at the same dose rates, with an MRT/BB/BB treatment schedule, were evaluated by measuring tumor volume and the induced immune response. Animal survival and normal skin reactions were also assessed.Results Clonogenic survival decreased with decreasing MRT dose rate, with most cell sparing at the highest dose rate (1000 Gy/s), indicating that lower dose rates could be more effective against tumors. However, no significant differences in in vivo tumor growth delay were observed in response to dose-rate variations. Decreased infiltration of irradiated tumors with leucocytes and their subpopulations was observed at the lower dose rates, including decreased expression of immune checkpoints PD-1/PD-L1 and prognostic marker CD103, which could impact the overall tumor response in vivo. The higher dose rates were associated with increased antitumor immunity. Early euthanasia of mice, as dictated by ethical endpoints, prevented long-term observation of differences in animal survival. Skin toxicity in the vicinity of irradiated tumors was mild and developed later at the highest MRT dose rate. Overall, MRT at 10 to 1000 Gy/s was tolerated similarly, despite dramatic changes in the dose rate.Conclusions These findings are promising for the clinical translation of MRT in combination with conventional RT, using emerging compact x-ray MRT sources with dose rates lower than those delivered by synchrotron sources.

Open Access CRIS of the University of Bern
Research Institute of Geodesy, Topography and Cartography (CZ)
Good health and well-being
Openalex Percentile: Top 93%
Radiation Therapy and Dosimetry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.