Suitability of Single-Branched Thoracic Endografts for the Treatment of Acute Type B Aortic Dissection—An Anatomical Feasibility and Comparative Study

<b>Objectives</b>: This study evaluated the anatomical suitability of two single-branched thoracic stent grafts-the Castor (Endovastec, China) and the Thoracic Branch Endoprosthesis (TBE, Gore, USA)-for proximal landing in aortic arch zone 2, including the left subclavian artery (LSA), in patients with acute type B aortic dissection (TBAD). While the TBE is currently available as an off-the-shelf device (26 main bodies, 8 branch configurations), the study also aimed to define the minimal number of configurations needed to treat most patients. The same approach was applied to the Castor stent graft, currently only available as a custom-made device (CMD), to assess its potential for off-the-shelf adaptation. <b>Methods:</b> A retrospective analysis was performed on computed tomographic angiographies of TBAD patients treated between 2004 and 2023. Exclusion criteria included type A or non-A-non-B dissections, isolated abdominal dissections, intramural hematomas, and lack of consent. Morphometric measurements were conducted using centerline analysis software. Suitability was defined per manufacturers' criteria and reported with 95% confidence intervals. <b>Results:</b> Among 100 TBAD cases, 82% (95% CI: 73.3-88.3%) were suitable for the Castor CMD with 74 configurations. Main causes of exclusion were short landing zones and atypical arch anatomies. With adjunctive procedures, 13 Castor configurations covered all morphologies; 34% could be treated off-the-shelf, and 48% required additional interventions. For the TBE, off-the-shelf suitability was 22%, increasing to 78% with adjunctive procedures (six main bodies, five branches). <b>Conclusions</b>: Both stent grafts are promising for proximal extension in TBAD. Reduced configuration availability necessitates more adjunctive procedures, impacting efficiency and cost.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2026-01-09
DOI
https://doi.org/10.3390/jcm15020558
Primary Topic
Aortic Disease and Treatment Approaches
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Suitability of Single-Branched Thoracic Endografts for the Treatment of Acute Type B Aortic Dissection—An Anatomical Feasibility and Comparative Study

Benedikt Reutersberg, Lorenz Meuli, Alexander Zimmerman, Philip Dueppers et al.
Journal of Clinical Medicine
Aortic Disease and Treatment Approaches
article

Suitability of Single-Branched Thoracic Endografts for the Treatment of Acute Type B Aortic Dissection—An Anatomical Feasibility and Comparative Study

Benedikt Reutersberg, Lorenz Meuli, Alexander Zimmerman, Philip Dueppers, Julius Lang
article en

Abstract

<b>Objectives</b>: This study evaluated the anatomical suitability of two single-branched thoracic stent grafts-the Castor (Endovastec, China) and the Thoracic Branch Endoprosthesis (TBE, Gore, USA)-for proximal landing in aortic arch zone 2, including the left subclavian artery (LSA), in patients with acute type B aortic dissection (TBAD). While the TBE is currently available as an off-the-shelf device (26 main bodies, 8 branch configurations), the study also aimed to define the minimal number of configurations needed to treat most patients. The same approach was applied to the Castor stent graft, currently only available as a custom-made device (CMD), to assess its potential for off-the-shelf adaptation. <b>Methods:</b> A retrospective analysis was performed on computed tomographic angiographies of TBAD patients treated between 2004 and 2023. Exclusion criteria included type A or non-A-non-B dissections, isolated abdominal dissections, intramural hematomas, and lack of consent. Morphometric measurements were conducted using centerline analysis software. Suitability was defined per manufacturers' criteria and reported with 95% confidence intervals. <b>Results:</b> Among 100 TBAD cases, 82% (95% CI: 73.3-88.3%) were suitable for the Castor CMD with 74 configurations. Main causes of exclusion were short landing zones and atypical arch anatomies. With adjunctive procedures, 13 Castor configurations covered all morphologies; 34% could be treated off-the-shelf, and 48% required additional interventions. For the TBE, off-the-shelf suitability was 22%, increasing to 78% with adjunctive procedures (six main bodies, five branches). <b>Conclusions</b>: Both stent grafts are promising for proximal extension in TBAD. Reduced configuration availability necessitates more adjunctive procedures, impacting efficiency and cost.

Journal of Clinical MedicineVol. 15(2)
Kantonsspital St. Gallen (CH), University Hospital of Zurich (CH), Spital Thurgau (Switzerland) (CH)
Reduced inequalities
Openalex Percentile: Top 93%
Aortic Disease and Treatment Approaches
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.