Comparative Study of King Vision and Vl3r (Hugemed) TM Video Laryngoscope for the Ease of Intubation in Adult Patients Undergoing General Anaesthesia for Elective Surgery

Abstract Background: It is challenging to intubate despite good visualization with hyperangulated blade of video laryngoscope. VL3 video laryngoscope with field angle 66° can save intubation time. We aim to evaluate performance of VL3 video laryngoscope in terms of intubation characteristics. Subjects and Methods: Ours is a prospective observational study. After Institutional Ethics Committee approval, 35 patients were recruited for intubation using VL3 video laryngoscope and King Vision Video laryngoscope each for nonemergency surgery. The primary outcome was intubation time while ease of intubation in terms of Intubation Difficulty Scale, POGO score and hemodynamic responses and complications were noted as secondary outcomes. Inclusion criteria: Ages 18- 60 years, either sex, weight- 45-70 kg, ASA I and II, all MPC grades. Exclusion criteria: past history of failed intubation, Ischaemic Heart Disease, Hypertension, raised ICP, spine /oral pathology, GE reflux. Results: The mean intubation time was 24.742 seconds. 20 patients (57.142%) had a IDS of 0 (easy) .and 30 patients had a POGO score of 1- (85.714%). There were 0 cases of failed intubation even in three attempts. The variations in haemodynamic parameters were found to be statistically insignificant. Discussion and Conclusion: Our mean intubation time was lesser than that of Toker MK2 et al with minimal haemodynamic variations .The VL3 video laryngoscope is an effective device for easy and quick intubation.

Authors

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-07-30
DOI
https://doi.org/10.5281/zenodo.18195798
Primary Topic
Airway Management and Intubation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Study of King Vision and Vl3r (Hugemed) TM Video Laryngoscope for the Ease of Intubation in Adult Patients Undergoing General Anaesthesia for Elective Surgery

International Journal of Medical Science and Advanced Clinical Research (IJMACR)
Zenodo (CERN European Organization for Nuclear Research)
Airway Management and Intubation Techniques
article

Comparative Study of King Vision and Vl3r (Hugemed) TM Video Laryngoscope for the Ease of Intubation in Adult Patients Undergoing General Anaesthesia for Elective Surgery

International Journal of Medical Science and Advanced Clinical Research (IJMACR)
article en

Abstract

Abstract Background: It is challenging to intubate despite good visualization with hyperangulated blade of video laryngoscope. VL3 video laryngoscope with field angle 66° can save intubation time. We aim to evaluate performance of VL3 video laryngoscope in terms of intubation characteristics. Subjects and Methods: Ours is a prospective observational study. After Institutional Ethics Committee approval, 35 patients were recruited for intubation using VL3 video laryngoscope and King Vision Video laryngoscope each for nonemergency surgery. The primary outcome was intubation time while ease of intubation in terms of Intubation Difficulty Scale, POGO score and hemodynamic responses and complications were noted as secondary outcomes. Inclusion criteria: Ages 18- 60 years, either sex, weight- 45-70 kg, ASA I and II, all MPC grades. Exclusion criteria: past history of failed intubation, Ischaemic Heart Disease, Hypertension, raised ICP, spine /oral pathology, GE reflux. Results: The mean intubation time was 24.742 seconds. 20 patients (57.142%) had a IDS of 0 (easy) .and 30 patients had a POGO score of 1- (85.714%). There were 0 cases of failed intubation even in three attempts. The variations in haemodynamic parameters were found to be statistically insignificant. Discussion and Conclusion: Our mean intubation time was lesser than that of Toker MK2 et al with minimal haemodynamic variations .The VL3 video laryngoscope is an effective device for easy and quick intubation.

Zenodo (CERN European Organization for Nuclear Research)
Advanced Pharma (US)
Openalex Percentile: Top 23%
Airway Management and Intubation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Comparative Study of King Vision and Vl3r (Hugemed) TM Video Laryngoscope for the Ease of Intubation in Adult Patients Undergoing General Anaesthesia for Elective Surgery — International Journal of Medical Science and Advanced Clinical Research (IJMACR) · Zenodo (CERN European Organization for Nuclear Research) (2025) | TGRS Research Map | TGRS