Ultrashort-Distance Internal Light Source-Integrated ECL-PEC Dual-Mode Molecular-Sensing Device for Highly Sensitive and Accurate Detection

High sensitivity and accuracy are pivotal for advancing photoelectrochemical (PEC) bioanalysis. However, the concurrent improvement of the two is difficult at present. In this work, by coupling an internal electrochemiluminescence (ECL) light source integrated ECL-PEC dual-mode detection with an enzyme-assisted target recycling amplification strategy, we developed a novel compact molecular-sensing device that achieves the concurrent enhancement of sensitivity and accuracy. Specifically, the luminol-Au NPs, as an internal ECL light source, were introduced onto Bi<sub>2</sub>WO<sub>6</sub> photoelectrode via a duplex-specific nuclease-assisted target recycling and hybridization process. This internal ECL light source could efficiently trigger the photoactivity of Bi<sub>2</sub>WO<sub>6</sub> photoelectrode in an ultrashort distance of ≤8.16 nm. In-depth research has shown that this device, with an internal ECL light source, can increase the PEC property by over 20 times, which is conducive to improving sensitivity. Meanwhile, the simultaneous output of the ECL signal from luminol-Au NPs and the PEC signal from Bi<sub>2</sub>WO<sub>6</sub> can be used for cross-validation to improve accuracy. This novel design ultimately realized the highly sensitive and accurate detection of microRNA-21 and its successful application in human serum samples. This work may open up a new prospect for the concurrent improvement of sensitivity and accuracy, as well as trace bioanalysis.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2026-01-09
DOI
https://doi.org/10.1021/acs.analchem.5c06089
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ultrashort-Distance Internal Light Source-Integrated ECL-PEC Dual-Mode Molecular-Sensing Device for Highly Sensitive and Accurate Detection

Rongrong Zhao, Xiaolong Fu, Zhi-zheng Li, B. L. Wang et al.
Analytical Chemistry
Advanced biosensing and bioanalysis techniques
article

Ultrashort-Distance Internal Light Source-Integrated ECL-PEC Dual-Mode Molecular-Sensing Device for Highly Sensitive and Accurate Detection

Rongrong Zhao, Xiaolong Fu, Zhi-zheng Li, B. L. Wang, Yuling Wang, Yang Lu, Shu-Wei Ren, Jun-Tao Cao
article en

Abstract

High sensitivity and accuracy are pivotal for advancing photoelectrochemical (PEC) bioanalysis. However, the concurrent improvement of the two is difficult at present. In this work, by coupling an internal electrochemiluminescence (ECL) light source integrated ECL-PEC dual-mode detection with an enzyme-assisted target recycling amplification strategy, we developed a novel compact molecular-sensing device that achieves the concurrent enhancement of sensitivity and accuracy. Specifically, the luminol-Au NPs, as an internal ECL light source, were introduced onto Bi<sub>2</sub>WO<sub>6</sub> photoelectrode via a duplex-specific nuclease-assisted target recycling and hybridization process. This internal ECL light source could efficiently trigger the photoactivity of Bi<sub>2</sub>WO<sub>6</sub> photoelectrode in an ultrashort distance of ≤8.16 nm. In-depth research has shown that this device, with an internal ECL light source, can increase the PEC property by over 20 times, which is conducive to improving sensitivity. Meanwhile, the simultaneous output of the ECL signal from luminol-Au NPs and the PEC signal from Bi<sub>2</sub>WO<sub>6</sub> can be used for cross-validation to improve accuracy. This novel design ultimately realized the highly sensitive and accurate detection of microRNA-21 and its successful application in human serum samples. This work may open up a new prospect for the concurrent improvement of sensitivity and accuracy, as well as trace bioanalysis.

Analytical ChemistryVol. 98(3)
Xinyang Normal University (CN), Nanomaterials Research (United States) (US), Xinyang Central Hospital (CN)
Openalex Percentile: Top 92%
Advanced biosensing and bioanalysis techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.