Seismic vulnerability assessment and retrofitting of code non-compliant mixed masonry-RC residential building

In seismically active zones like Nepal, it is utmost for the structures to be designed by following proper seismic design criteria. However, the majority of older unreinforced buildings in Nepal are non-engineered or semi-engineered constructions with inadequate seismic detailing. A detailed visual assessment of the Panauti municipality area, led to the identification of a unique building typology which belonged to “non-code compliant mixed Masonry-RC” typology. Finite element (FE) model and pushover analysis was performed for the building, followed by generation of fragility curves and sensitivity analysis. Since the building exhibited vulnerability against the seismic forces, four different retrofitting measures were considered to assess their effectiveness. The result revealed that a combination of full splint and bandage system provides highest strengthening (85% base shear enhancement) and energy absorption capacity (33% greater), while diagonal splint + bandage system provides highest ductility (increment by 174%), whereas splint only retrofit scheme provides highest base shear enhancement per USD (57% per 1000 USD). The research concluded that diagonal splint + bandage is an optimal retrofitting scheme that provide balance on strength, ductility, and economy of the project. The study demonstrated the efficacy of ferrocement bands as a cost-effective strengthening solution for unreinforced masonry buildings in seismically active regions. The findings provide valuable insights for choosing effective retrofitting strategy considering seismicity and economy of the project and the strength, ductility and energy absorption of splint & bandage retrofitting arrangement.

Authors

Institutions

Publication Details

Journal
Advances in Structural Engineering
Published
2026-01-09
DOI
https://doi.org/10.1177/13694332261415682
Citations
1
Primary Topic
Masonry and Concrete Structural Analysis
Type
article
Field-Weighted Citation Impact
19.37
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Seismic vulnerability assessment and retrofitting of code non-compliant mixed masonry-RC residential building

Kshitij C. Shrestha, Suman Poudel
1 citations
Advances in Structural Engineering
Masonry and Concrete Structural Analysis
19.37
article

Seismic vulnerability assessment and retrofitting of code non-compliant mixed masonry-RC residential building

Kshitij C. Shrestha, Suman Poudel
article en
1 citations

Abstract

In seismically active zones like Nepal, it is utmost for the structures to be designed by following proper seismic design criteria. However, the majority of older unreinforced buildings in Nepal are non-engineered or semi-engineered constructions with inadequate seismic detailing. A detailed visual assessment of the Panauti municipality area, led to the identification of a unique building typology which belonged to “non-code compliant mixed Masonry-RC” typology. Finite element (FE) model and pushover analysis was performed for the building, followed by generation of fragility curves and sensitivity analysis. Since the building exhibited vulnerability against the seismic forces, four different retrofitting measures were considered to assess their effectiveness. The result revealed that a combination of full splint and bandage system provides highest strengthening (85% base shear enhancement) and energy absorption capacity (33% greater), while diagonal splint + bandage system provides highest ductility (increment by 174%), whereas splint only retrofit scheme provides highest base shear enhancement per USD (57% per 1000 USD). The research concluded that diagonal splint + bandage is an optimal retrofitting scheme that provide balance on strength, ductility, and economy of the project. The study demonstrated the efficacy of ferrocement bands as a cost-effective strengthening solution for unreinforced masonry buildings in seismically active regions. The findings provide valuable insights for choosing effective retrofitting strategy considering seismicity and economy of the project and the strength, ductility and energy absorption of splint & bandage retrofitting arrangement.

Advances in Structural Engineering
Tribhuvan University (NP)
Sustainable cities and communities
Openalex Percentile: Top 3%
Masonry and Concrete Structural Analysis
19.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.