Bone remodelling comparison between normal pedicle screw and expandable pedicle screw instrumented L4-L5 vertebrae: a preclinical study using FE analysis

Lumbar spinal disorder is a chief cause of disability leading to medical intervention, specifically for elderly people worldwide. The present study aims to investigate and evaluate the biomechanical performance of the expandable pedicle screw vis-à-vis normal pedicle screw with a focus on the load transfer and bone remodelling around the lumbar vertebra. A strain energy density (SED)-based bone remodelling algorithm in combination with three-dimensional finite element (FE) models of intact and implanted lumbar spine FSU was used to investigate the changes in bone density around the screws. The loading (flexion, extension, torsion, lateral bending) and boundary conditions influenced strain, and SED distribution within the FSU. In case of normal pedicle screws, bone apposition was primarily concentrated near the screw insertion region in both L4 (60%-80%) and L5 (30%-90%) vertebra. Bone resorption was estimated to be in the posterior region, near screw length in L4 (10%-45%) and in central anterior right side and posteriorly in L5 vertebra (20%-60%). For expandable pedicle screws, bone apposition was predicted in a relatively larger area in central anterior screw insertion region for L4 vertebra (50%-75%) and L5 vertebra (40%-75%). Bone resorption was found in the central anterior right side as well as on posterior side of L4-L5 vertebra although the area was comparatively less. Bone apposition was significantly greater near the cage insertion area for both pedicle types. It was estimated that the average bone density increase was greater in case of expandable pedicle screws than that for normal pedicle screws. Also, the average density in L5 vertebra was higher than the L4 vertebra. The overall result appears to favour expandable pedicles over normal ones so far as bone remodelling is concerned.

Authors

Institutions

Publication Details

Journal
Medical Engineering & Physics
Published
2026-01-01
DOI
https://doi.org/10.1088/1873-4030/ae1825
Primary Topic
Spinal Fractures and Fixation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Bone remodelling comparison between normal pedicle screw and expandable pedicle screw instrumented L4-L5 vertebrae: a preclinical study using FE analysis

Soumyadeep Sarkar, Souptick Chanda, Devismita Sanjay
Medical Engineering & Physics
Spinal Fractures and Fixation Techniques
article

Bone remodelling comparison between normal pedicle screw and expandable pedicle screw instrumented L4-L5 vertebrae: a preclinical study using FE analysis

Soumyadeep Sarkar, Souptick Chanda, Devismita Sanjay
article en

Abstract

Lumbar spinal disorder is a chief cause of disability leading to medical intervention, specifically for elderly people worldwide. The present study aims to investigate and evaluate the biomechanical performance of the expandable pedicle screw vis-à-vis normal pedicle screw with a focus on the load transfer and bone remodelling around the lumbar vertebra. A strain energy density (SED)-based bone remodelling algorithm in combination with three-dimensional finite element (FE) models of intact and implanted lumbar spine FSU was used to investigate the changes in bone density around the screws. The loading (flexion, extension, torsion, lateral bending) and boundary conditions influenced strain, and SED distribution within the FSU. In case of normal pedicle screws, bone apposition was primarily concentrated near the screw insertion region in both L4 (60%-80%) and L5 (30%-90%) vertebra. Bone resorption was estimated to be in the posterior region, near screw length in L4 (10%-45%) and in central anterior right side and posteriorly in L5 vertebra (20%-60%). For expandable pedicle screws, bone apposition was predicted in a relatively larger area in central anterior screw insertion region for L4 vertebra (50%-75%) and L5 vertebra (40%-75%). Bone resorption was found in the central anterior right side as well as on posterior side of L4-L5 vertebra although the area was comparatively less. Bone apposition was significantly greater near the cage insertion area for both pedicle types. It was estimated that the average bone density increase was greater in case of expandable pedicle screws than that for normal pedicle screws. Also, the average density in L5 vertebra was higher than the L4 vertebra. The overall result appears to favour expandable pedicles over normal ones so far as bone remodelling is concerned.

Medical Engineering & PhysicsVol. 147(1)
Indian Institute of Technology Guwahati (IN)
Openalex Percentile: Top 93%
Spinal Fractures and Fixation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.