Evaluating Duplicate Results Demonstrates Differences Between Direct and Canister Sampling Methods

Abstract Field duplicates of environmental samples are collected to evaluate field and laboratory precision. This study used field duplicate results to assess whether samples analyzed for volatile organic compounds collected using reusable summa canisters exhibit carryover contamination when compared to results for samples collected using direct sampling methods (e.g., soil gas collected by mobile laboratories via dedicated tubing and syringes or groundwater collected using disposable vials). This study utilized data sets of groundwater, soil gas, and indoor air from samples collected between 2000 and 2024 from multiple project sites and analyzed by different analytical laboratories. Volatile organic compound data were evaluated by sampling method (direct or reusable canister), analytical method, and medium following a similar approach to the one described in a prior study by McHugh et al. (2018). This evaluation included assessing the magnitude of the differences between primary and duplicate sample results by calculating percent differences and comparing the number of single‐detect pairs versus non‐detect pairs, which could be an indication of carryover contamination. Results showed that water samples collected using disposable vials and soil gas samples collected using direct sampling methods had greater precision (i.e., lower percent differences) and lower occurrences of single‐detect pairs compared to soil gas or indoor air samples collected using evacuated canisters; confirming that reusable canisters may contain carryover contamination. Other factors contributing to uncertainty (i.e., low detected concentrations, sampling equipment certification process, quality control procedures, and laboratory best practices) were also considered to explain the discrepancies identified in this study.

Authors

Publication Details

Journal
Groundwater Monitoring & Remediation
Published
2026-01-09
DOI
https://doi.org/10.1111/gwmr.70030
Primary Topic
Pesticide Residue Analysis and Safety
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluating Duplicate Results Demonstrates Differences Between Direct and Canister Sampling Methods

Isabella Polenghi‐Gross, Jane A. Parkin Kullmann
Groundwater Monitoring & Remediation
Pesticide Residue Analysis and Safety
article

Evaluating Duplicate Results Demonstrates Differences Between Direct and Canister Sampling Methods

Isabella Polenghi‐Gross, Jane A. Parkin Kullmann
article en

Abstract

Abstract Field duplicates of environmental samples are collected to evaluate field and laboratory precision. This study used field duplicate results to assess whether samples analyzed for volatile organic compounds collected using reusable summa canisters exhibit carryover contamination when compared to results for samples collected using direct sampling methods (e.g., soil gas collected by mobile laboratories via dedicated tubing and syringes or groundwater collected using disposable vials). This study utilized data sets of groundwater, soil gas, and indoor air from samples collected between 2000 and 2024 from multiple project sites and analyzed by different analytical laboratories. Volatile organic compound data were evaluated by sampling method (direct or reusable canister), analytical method, and medium following a similar approach to the one described in a prior study by McHugh et al. (2018). This evaluation included assessing the magnitude of the differences between primary and duplicate sample results by calculating percent differences and comparing the number of single‐detect pairs versus non‐detect pairs, which could be an indication of carryover contamination. Results showed that water samples collected using disposable vials and soil gas samples collected using direct sampling methods had greater precision (i.e., lower percent differences) and lower occurrences of single‐detect pairs compared to soil gas or indoor air samples collected using evacuated canisters; confirming that reusable canisters may contain carryover contamination. Other factors contributing to uncertainty (i.e., low detected concentrations, sampling equipment certification process, quality control procedures, and laboratory best practices) were also considered to explain the discrepancies identified in this study.

Groundwater Monitoring & Remediation
Openalex Percentile: Top 93%
Pesticide Residue Analysis and Safety
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Evaluating Duplicate Results Demonstrates Differences Between Direct and Canister Sampling Methods — Isabella Polenghi‐Gross, Jane A. Parkin Kullmann · Groundwater Monitoring & Remediation (2026) | TGRS Research Map | TGRS