Evaluation of the impact of e-beam and X-ray irradiation conditions on radical generation in PE/EVOH/PE multilayer film

Sterilization of biopharmaceutical products has commonly employed gamma radiation from cobalt-60, a radioisotope with associated security and supply chain risks. Increased use of non-radioisotope alternative ionizing energy technologies, such as electron beam (e-beam) and X-rays, is promising but has been hindered by lack of thorough evaluation of the compatibility of these techniques with product materials. This study investigates radical generation in a polyethylene (PE)/ethylene-vinyl alcohol copolymer (EVOH)/PE multilayer film product (Sartorius Flexsafe® with the S80 film) under varying e-beam and X-ray irradiation conditions to address data gaps for these materials and technologies. Utilizing a full factorial design of experiments (DoE), we examined the effects of irradiation technology, dose level, dose rate, processing temperature, and ambient oxygen concentration on radical formation, as quantified by electron spin resonance (ESR). Our results indicate that the type of ionizing technology (e-beam vs. X-ray) does not significantly affect radical concentration generation in the materials. However, higher doses and lower temperatures were found to correlate with increased radical concentrations, while elevated oxygen levels effectively suppressed radicals through a presumed scavenging mechanism. For e-beam processing, a higher dose rate reduced radical accumulation, while the opposite trend was found for X-ray irradiation. Complementary Fourier-transform infrared spectroscopy (FTIR) and principal component analysis (PCA) revealed subtle oxidation differences of PE under specific irradiation conditions. • Electron beam and X-ray use increasing for sterilization of multilayer films • Ionizing energy generates reactive radicals measurable using ESR • Effects of source, dose, dose rate, temperature, and oxygen considered • Radiation source does not affect radical generation in PE/EVOH/PE • Design of experiment used to assess combined effects

Authors

Institutions

Publication Details

Journal
Radiation Physics and Chemistry
Published
2026-01-09
DOI
https://doi.org/10.1016/j.radphyschem.2026.113610
Primary Topic
Radiation Effects and Dosimetry
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of the impact of e-beam and X-ray irradiation conditions on radical generation in PE/EVOH/PE multilayer film

Samuel Dorey, Leonard S. Fifield, Nicolas Ludwig, Fabien Girard et al.
Radiation Physics and Chemistry
Radiation Effects and Dosimetry
article

Evaluation of the impact of e-beam and X-ray irradiation conditions on radical generation in PE/EVOH/PE multilayer film

Samuel Dorey, Leonard S. Fifield, Nicolas Ludwig, Fabien Girard, Yelin Ni, Blanche Krieguer, Sylvain R.A. Marque, Nathalie Dupuy
article en

Abstract

Sterilization of biopharmaceutical products has commonly employed gamma radiation from cobalt-60, a radioisotope with associated security and supply chain risks. Increased use of non-radioisotope alternative ionizing energy technologies, such as electron beam (e-beam) and X-rays, is promising but has been hindered by lack of thorough evaluation of the compatibility of these techniques with product materials. This study investigates radical generation in a polyethylene (PE)/ethylene-vinyl alcohol copolymer (EVOH)/PE multilayer film product (Sartorius Flexsafe® with the S80 film) under varying e-beam and X-ray irradiation conditions to address data gaps for these materials and technologies. Utilizing a full factorial design of experiments (DoE), we examined the effects of irradiation technology, dose level, dose rate, processing temperature, and ambient oxygen concentration on radical formation, as quantified by electron spin resonance (ESR). Our results indicate that the type of ionizing technology (e-beam vs. X-ray) does not significantly affect radical concentration generation in the materials. However, higher doses and lower temperatures were found to correlate with increased radical concentrations, while elevated oxygen levels effectively suppressed radicals through a presumed scavenging mechanism. For e-beam processing, a higher dose rate reduced radical accumulation, while the opposite trend was found for X-ray irradiation. Complementary Fourier-transform infrared spectroscopy (FTIR) and principal component analysis (PCA) revealed subtle oxidation differences of PE under specific irradiation conditions. • Electron beam and X-ray use increasing for sterilization of multilayer films • Ionizing energy generates reactive radicals measurable using ESR • Effects of source, dose, dose rate, temperature, and oxygen considered • Radiation source does not affect radical generation in PE/EVOH/PE • Design of experiment used to assess combined effects

Radiation Physics and ChemistryVol. 243
Centre National de la Recherche Scientifique (FR), Pacific Northwest National Laboratory (US), Aix-Marseille Université (FR), Institut de Recherche pour le Développement (FR)
Affordable and clean energy
Openalex Percentile: Top 93%
Radiation Effects and Dosimetry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.