Recurrent coronary artery in-stent restenosis caused by metal allergy: a case report

This article describes the case of a middle-aged woman who developed recurrent in-stent restenosis (ISR) due to metal allergy. The first ISR occurred after implantation of a nickel-rich Medtronic Endeavor Resolute stent (35% nickel, 35% cobalt, and 20% chromium). A skin patch test revealed a strong nickel allergy (++), with no allergic reaction to cobalt. Nickel allergy was considered to be the cause of the first ISR. Then, a drug-coated balloon platinum-chromium alloy stent was implanted, and ISR occurred again during follow-up. The article discusses this special case and clinically relevant management options. This case highlights a scenario with refractory in-stent restenosis persisting despite various treatment strategies, including stents with different metal components, drug-coated balloons, and intensive drug therapy.

Authors

Institutions

Publication Details

Journal
Frontiers in Cardiovascular Medicine
Published
2026-01-09
DOI
https://doi.org/10.3389/fcvm.2025.1693234
Primary Topic
Contact Dermatitis and Allergies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Recurrent coronary artery in-stent restenosis caused by metal allergy: a case report

Yi Feng, Lijuan Chen, Qiming Dai, Zhengbang Dong et al.
Frontiers in Cardiovascular Medicine
Contact Dermatitis and Allergies
article

Recurrent coronary artery in-stent restenosis caused by metal allergy: a case report

Yi Feng, Lijuan Chen, Qiming Dai, Zhengbang Dong, Genshan Ma, Yang Li
article en

Abstract

This article describes the case of a middle-aged woman who developed recurrent in-stent restenosis (ISR) due to metal allergy. The first ISR occurred after implantation of a nickel-rich Medtronic Endeavor Resolute stent (35% nickel, 35% cobalt, and 20% chromium). A skin patch test revealed a strong nickel allergy (++), with no allergic reaction to cobalt. Nickel allergy was considered to be the cause of the first ISR. Then, a drug-coated balloon platinum-chromium alloy stent was implanted, and ISR occurred again during follow-up. The article discusses this special case and clinically relevant management options. This case highlights a scenario with refractory in-stent restenosis persisting despite various treatment strategies, including stents with different metal components, drug-coated balloons, and intensive drug therapy.

Frontiers in Cardiovascular MedicineVol. 12
Zhongda Hospital Southeast University (CN)
National Natural Science Foundation of China
Good health and well-being
Openalex Percentile: Top 93%
Contact Dermatitis and Allergies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Recurrent coronary artery in-stent restenosis caused by metal allergy: a case report — Yi Feng, Lijuan Chen, et al. · Frontiers in Cardiovascular Medicine (2026) | TGRS Research Map | TGRS