<i>In vivo</i> detectability of tau‐PET tracers in Alzheimer's disease

Abstract Background Tau‐PET tracers are essential for visualizing pathology in Alzheimer's (AD). High detectability to tau is crucial for early detection and monitoring of tau deposition. This study compares the noise to dynamic range ratio (NRR) of [ 18 F]FTP, [ 18 F]MK6240, [ 18 F]PI2620, and [ 18 F]RO948, cross‐sectionally and longitudinally. Methods 460 individuals from the HEAD study (23 cognitively unimpaired (CU) young, 249 CU old and 188 cognitively impaired) underwent [ 18 F]FTP and [ 18 F]MK6240 tau‐PET scans; 94 additionally received [ 18 F]PI2620 and [ 18 F]RO948. A subset of 28 individuals (15 CU and 13 CI) underwent [ 18 F]FTP and [ 18 F]MK6240 follow‐up scans (1.5 ± 0.1 years later). Annual change was measured as [(followup‐baseline)/time between scans]. Noise was calculated as the standard deviation (SD) of CU Aβ‐ participants aged ≤65 (SD CUAβ‐≤65 ). The dynamic range was calculated as the SD across all subjects (SD range ). A lower the NRR (=SD CUAβ‐≤65 /SD range ) indicates more detectability. Analyses were performed at both region‐of‐interest and voxel‐wise levels. Results Across the whole cohort, [ 18 F]MK6240 exhibited lower NRR than [ 18 F]FTP in all regions. Voxel‐wise, differences were most pronounced in the frontal medial temporal regions (Figure 1). Within the four‐tracers subset, [ 18 F]PI2620 and [ 18 F]FTP showed the highest NRR in Braak II, followed by [ 18 F]RO948 and [ 18 F]MK6240. In Braak IV‐VI, [ 18 F]MK6240 consistently demonstrated the lowest values, followed by [ 18 F]PI2620, [ 18 F]FTP and [ 18 F]RO948. Similarly, in metatemporal‐ROI and Braak III, [ 18 F]MK6240 remained the lowest, however followed by [ 18 F]FTP, [ 18 F]PI2620 and [ 18 F]RO948 (Figure 2). Lower [ 18 F]MK6240 NRR was due to larger SD range , while [ 18 F]FTP's lower values stemmed from smaller SD CUAβ‐≤65 . Conversely, high [ 18 F]PI2620 and [ 18 F]RO948 values are driven by larger SD CUAβ‐≤65 . Longitudinal analyses further confirmed that [ 18 F]MK6240 exhibited the lowest NRR across the entire brain, including AD‐related regions, with voxel‐wise differences mainly in the temporal and parietal lobes. Conclusion Tau‐PET tracers exhibit significant variability in detectability. [ 18 F]MK6240 consistently demonstrated lower NRR, implying better detectability across all regions, cross‐sectionally and longitudinally. Despite differences in NRR, [ 18 F]FTP, [ 18 F]RO948 and [ 18 F]PI2620 followed similar pattern. These results provide insights into the differential tracer detectability, helping guide their optimal use in detecting and tracking tau pathology. Ongoing follow‐up scans will further clarify longitudinal tracer detectability and its implications for tau progression in AD.

Authors

Institutions

Publication Details

Journal
Alzheimer s & Dementia
Published
2025-12-01
DOI
https://doi.org/10.1002/alz70856_106041
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In vivo detectability of tau‐PET tracers in Alzheimer's disease

Val J. Lowe, Nesrine Rahmouni, Suzanne L. Baker, Firoza Zubeida Lussier et al.
Alzheimer s & Dementia
Medical Imaging Techniques and Applications
article

In vivo detectability of tau‐PET tracers in Alzheimer's disease

Val J. Lowe, Nesrine Rahmouni, Suzanne L. Baker, Firoza Zubeida Lussier, Tissot Cecile, J. K. M. ller Stevenson, Jacob Ziontz, David Soleimani‐Meigooni, Hsin‐Yeh Tsai, Lydia Trudel, Peiwei Liu, Arthur Macedo, William J. Jagust, Joseph Therriault, Brian A. Gordon, Stijn Servaes, William E Klunk, Hwamee Oh, Belen Pascual, Pedro Rosa‐Neto
article en

Abstract

Abstract Background Tau‐PET tracers are essential for visualizing pathology in Alzheimer's (AD). High detectability to tau is crucial for early detection and monitoring of tau deposition. This study compares the noise to dynamic range ratio (NRR) of [ 18 F]FTP, [ 18 F]MK6240, [ 18 F]PI2620, and [ 18 F]RO948, cross‐sectionally and longitudinally. Methods 460 individuals from the HEAD study (23 cognitively unimpaired (CU) young, 249 CU old and 188 cognitively impaired) underwent [ 18 F]FTP and [ 18 F]MK6240 tau‐PET scans; 94 additionally received [ 18 F]PI2620 and [ 18 F]RO948. A subset of 28 individuals (15 CU and 13 CI) underwent [ 18 F]FTP and [ 18 F]MK6240 follow‐up scans (1.5 ± 0.1 years later). Annual change was measured as [(followup‐baseline)/time between scans]. Noise was calculated as the standard deviation (SD) of CU Aβ‐ participants aged ≤65 (SD CUAβ‐≤65 ). The dynamic range was calculated as the SD across all subjects (SD range ). A lower the NRR (=SD CUAβ‐≤65 /SD range ) indicates more detectability. Analyses were performed at both region‐of‐interest and voxel‐wise levels. Results Across the whole cohort, [ 18 F]MK6240 exhibited lower NRR than [ 18 F]FTP in all regions. Voxel‐wise, differences were most pronounced in the frontal medial temporal regions (Figure 1). Within the four‐tracers subset, [ 18 F]PI2620 and [ 18 F]FTP showed the highest NRR in Braak II, followed by [ 18 F]RO948 and [ 18 F]MK6240. In Braak IV‐VI, [ 18 F]MK6240 consistently demonstrated the lowest values, followed by [ 18 F]PI2620, [ 18 F]FTP and [ 18 F]RO948. Similarly, in metatemporal‐ROI and Braak III, [ 18 F]MK6240 remained the lowest, however followed by [ 18 F]FTP, [ 18 F]PI2620 and [ 18 F]RO948 (Figure 2). Lower [ 18 F]MK6240 NRR was due to larger SD range , while [ 18 F]FTP's lower values stemmed from smaller SD CUAβ‐≤65 . Conversely, high [ 18 F]PI2620 and [ 18 F]RO948 values are driven by larger SD CUAβ‐≤65 . Longitudinal analyses further confirmed that [ 18 F]MK6240 exhibited the lowest NRR across the entire brain, including AD‐related regions, with voxel‐wise differences mainly in the temporal and parietal lobes. Conclusion Tau‐PET tracers exhibit significant variability in detectability. [ 18 F]MK6240 consistently demonstrated lower NRR, implying better detectability across all regions, cross‐sectionally and longitudinally. Despite differences in NRR, [ 18 F]FTP, [ 18 F]RO948 and [ 18 F]PI2620 followed similar pattern. These results provide insights into the differential tracer detectability, helping guide their optimal use in detecting and tracking tau pathology. Ongoing follow‐up scans will further clarify longitudinal tracer detectability and its implications for tau progression in AD.

Alzheimer s & DementiaVol. 21(S2)
Houston Methodist (US), Lawrence Berkeley National Laboratory (US), University of Pittsburgh (US), University of California, San Francisco (US), Washington University in St. Louis (US), Brown University (US), Mayo Clinic in Arizona (US), McGill University (CA), University of California, Berkeley (US)
Openalex Percentile: Top 29%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.