A 10 kHz laser-induced fluorescence system for time-resolved detection of reactive intermediates via proxy measurements

We present a high-repetition-rate laser-induced fluorescence (LIF) instrument operating at 10 kHz for measuring reaction kinetics of species that dissociate to produce LIF-detectable products. The technique employs a tunable dye laser to excite OH radicals with fluorescence detected by a photomultiplier tube, providing 100 μs temporal resolution. The high repetition rate enables rapid accumulation of thousands of laser shots, achieving high sensitivity and excellent signal-to-noise ratios. We demonstrate this proxy detection approach by monitoring Criegee intermediates (CIs) through their unimolecular decomposition to OH radicals, where the OH temporal profile directly reflects CI decay kinetics. The method is validated using the well-characterized syn-CH3CHOO + SO2 reaction in a flow reactor, yielding rate coefficients consistent with literature values. This technique extends conventional LIF measurements to species that are not directly detectable but produce LIF-active fragments upon decomposition, offering a sensitive, time-resolved approach for studying reactive intermediates with applications in atmospheric and combustion chemistry.

Authors

Institutions

Publication Details

Journal
Review of Scientific Instruments
Published
2026-01-01
DOI
https://doi.org/10.1063/5.0302605
Primary Topic
Combustion and flame dynamics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A 10 kHz laser-induced fluorescence system for time-resolved detection of reactive intermediates via proxy measurements

M J Li, Y. Liu, Chunlei Xiao, Xueming Yang et al.
Review of Scientific Instruments
Combustion and flame dynamics
article

A 10 kHz laser-induced fluorescence system for time-resolved detection of reactive intermediates via proxy measurements

M J Li, Y. Liu, Chunlei Xiao, Xueming Yang, Haotian Jiang, Weiqing Zhang, Hongwei Li
article en

Abstract

We present a high-repetition-rate laser-induced fluorescence (LIF) instrument operating at 10 kHz for measuring reaction kinetics of species that dissociate to produce LIF-detectable products. The technique employs a tunable dye laser to excite OH radicals with fluorescence detected by a photomultiplier tube, providing 100 μs temporal resolution. The high repetition rate enables rapid accumulation of thousands of laser shots, achieving high sensitivity and excellent signal-to-noise ratios. We demonstrate this proxy detection approach by monitoring Criegee intermediates (CIs) through their unimolecular decomposition to OH radicals, where the OH temporal profile directly reflects CI decay kinetics. The method is validated using the well-characterized syn-CH3CHOO + SO2 reaction in a flow reactor, yielding rate coefficients consistent with literature values. This technique extends conventional LIF measurements to species that are not directly detectable but produce LIF-active fragments upon decomposition, offering a sensitive, time-resolved approach for studying reactive intermediates with applications in atmospheric and combustion chemistry.

Review of Scientific InstrumentsVol. 97(1)
University of Science and Technology of China (CN), Hefei University of Technology (CN), Dalian Institute of Chemical Physics (CN), Dalian University of Technology (CN), Southern University of Science and Technology (CN), Hefei University (CN), Dalian University (CN)
Life below water
Openalex Percentile: Top 93%
Combustion and flame dynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A 10 kHz laser-induced fluorescence system for time-resolved detection of reactive intermediates via proxy measurements — M J Li, Y. Liu, et al. · Review of Scientific Instruments (2026) | TGRS Research Map | TGRS