Resonant core–shell magnetoelectric nanoparticles as sensors of neural magnetic activity: a computational study

Measuring the weak magnetic fields generated by spontaneous biological activity, such as those produced in the brain or heart, offers complementary information to conventional electrophysiological techniques, as electroencephalography and electrocardiography. Nevertheless, the widespread clinical use of biomagnetic sensing is hindered by the bulky and costly technology currently available, including SQUID-based and optically pumped magnetometers. In recent years magnetoelectric materials have been explored as highly sensitive, room-temperature magnetic field sensors, offering a compelling alternative to conventional approaches. Here, we investigate the feasibility of using resonant magnetoelectric nanoparticles (MENPs) as nanoscale magnetic sensors by exploiting the delta-E effect, in which magnetic-field-induced changes in elastic properties, i.e. Young's modulus, shift the nanoparticle's resonance frequency. Using a computational modeling approach, we first developed and characterized a core-shell MENP model. We then identified its natural resonance frequencies in the GHz range, evaluated its sensitivity to external magnetic field variations, and determined the optimal bias static magnetic field and core radius for maximum sensitivity. Finally, we assessed the performance of the optimized nanoparticle in detecting neural-level magnetic fields. Our simulations demonstrate that MENP can achieve a maximum sensitivity of 2.59 Hz/nT for a core diameter of 50 nm under a bias static magnetic field of 1000 Oe. These findings highlight both the feasibility of exploiting the delta-E effect in MENPs and the tunability of their structural parameters, which could be tailored for specific applications. In conclusion, this work set the theoretical groundwork for the development of cutting-edge, wireless and non-invasive nanoscale magnetic sensors for neural interfacing and biomedical signals sensing.

Authors

Institutions

Publication Details

Journal
Bioelectronic Medicine
Published
2026-01-09
DOI
https://doi.org/10.1186/s42234-025-00198-1
Citations
1
Primary Topic
Multiferroics and related materials
Type
article
Field-Weighted Citation Impact
11.44
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Resonant core–shell magnetoelectric nanoparticles as sensors of neural magnetic activity: a computational study

Serena Fiocchi, P. Ravazzani, Giulia Caiani, Emma Chiaramello
1 citations
Bioelectronic Medicine
Multiferroics and related materials
11.44
article

Resonant core–shell magnetoelectric nanoparticles as sensors of neural magnetic activity: a computational study

Serena Fiocchi, P. Ravazzani, Giulia Caiani, Emma Chiaramello
article en
1 citations

Abstract

Measuring the weak magnetic fields generated by spontaneous biological activity, such as those produced in the brain or heart, offers complementary information to conventional electrophysiological techniques, as electroencephalography and electrocardiography. Nevertheless, the widespread clinical use of biomagnetic sensing is hindered by the bulky and costly technology currently available, including SQUID-based and optically pumped magnetometers. In recent years magnetoelectric materials have been explored as highly sensitive, room-temperature magnetic field sensors, offering a compelling alternative to conventional approaches. Here, we investigate the feasibility of using resonant magnetoelectric nanoparticles (MENPs) as nanoscale magnetic sensors by exploiting the delta-E effect, in which magnetic-field-induced changes in elastic properties, i.e. Young's modulus, shift the nanoparticle's resonance frequency. Using a computational modeling approach, we first developed and characterized a core-shell MENP model. We then identified its natural resonance frequencies in the GHz range, evaluated its sensitivity to external magnetic field variations, and determined the optimal bias static magnetic field and core radius for maximum sensitivity. Finally, we assessed the performance of the optimized nanoparticle in detecting neural-level magnetic fields. Our simulations demonstrate that MENP can achieve a maximum sensitivity of 2.59 Hz/nT for a core diameter of 50 nm under a bias static magnetic field of 1000 Oe. These findings highlight both the feasibility of exploiting the delta-E effect in MENPs and the tunability of their structural parameters, which could be tailored for specific applications. In conclusion, this work set the theoretical groundwork for the development of cutting-edge, wireless and non-invasive nanoscale magnetic sensors for neural interfacing and biomedical signals sensing.

Bioelectronic MedicineVol. 12(1)
Institute of Electronics, Computer and Telecommunication Engineering (IT), National Research Council (IT), Politecnico di Milano (IT)
Openalex Percentile: Top 5%
Multiferroics and related materials
11.44
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.