Colorimetric and Fluorimetric Multiple Metal Ion Sensing Using Naphthalene‐Based Schiff Base

ABSTRACT A novel Schiff base ligand functionalized with a naphthalene moiety has been developed as colorimetric and fluorimetric sensor for the selective detection of multiple metal ions. The coordination of four metal ions (Fe 2+ , Fe 3+ , Co 2+ , and Ni 2+ ) induces an individual color change in solution, while fluorescence is emitted upon the addition of seven other metal ions (Mg 2+ , Ca 2+ , Cd 2+ , Zn 2+ , Al 3+ , Ga 3+ , and In 3+ ). The reliability of the chemosensor was evaluated through competition experiments with a panoply of different cations. The nature of the solvent was revealed to have an impact on the fluorescence properties but not on color changes, whereas the type of counterion did not influence the colorimetric and fluorimetric detection.

Authors

Institutions

Publication Details

Journal
Helvetica Chimica Acta
Published
2026-01-08
DOI
https://doi.org/10.1002/hlca.202500175
Citations
1
Primary Topic
Molecular Sensors and Ion Detection
Type
article
Field-Weighted Citation Impact
16.26

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Colorimetric and Fluorimetric Multiple Metal Ion Sensing Using Naphthalene‐Based Schiff Base

Aurélien Crochet, Katharina M. Fromm, Jocelyn Pradegan
1 citations
Helvetica Chimica Acta
Molecular Sensors and Ion Detection
16.26
article

Colorimetric and Fluorimetric Multiple Metal Ion Sensing Using Naphthalene‐Based Schiff Base

Aurélien Crochet, Katharina M. Fromm, Jocelyn Pradegan
article en
1 citations

Abstract

ABSTRACT A novel Schiff base ligand functionalized with a naphthalene moiety has been developed as colorimetric and fluorimetric sensor for the selective detection of multiple metal ions. The coordination of four metal ions (Fe 2+ , Fe 3+ , Co 2+ , and Ni 2+ ) induces an individual color change in solution, while fluorescence is emitted upon the addition of seven other metal ions (Mg 2+ , Ca 2+ , Cd 2+ , Zn 2+ , Al 3+ , Ga 3+ , and In 3+ ). The reliability of the chemosensor was evaluated through competition experiments with a panoply of different cations. The nature of the solvent was revealed to have an impact on the fluorescence properties but not on color changes, whereas the type of counterion did not influence the colorimetric and fluorimetric detection.

Helvetica Chimica ActaVol. 109(3)
University of Fribourg (CH)
National Science Foundation, Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung, Université de Fribourg
Openalex Percentile: Top 3%
Molecular Sensors and Ion Detection
16.26
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Colorimetric and Fluorimetric Multiple Metal Ion Sensing Using Naphthalene‐Based Schiff Base — Aurélien Crochet, Katharina M. Fromm, et al. · Helvetica Chimica Acta (2026) | TGRS Research Map | TGRS