Quantification of Droplet Aerosol Generation During Phacoemulsification and Pars Plana Vitrectomy

Introduction Intraocular procedures such as phacoemulsification and pars plana vitrectomy (PPV) may generate fine droplet aerosols that are relevant to infection control, particularly in the context of SARS-CoV-2. Data on aerosol production during cataract and vitrectomy surgery, especially in human tissue and with different wound constructions, remain limited. This study used a high-sensitivity optical particle spectrometer to quantify droplet aerosols (0.12-8.00 μm in diameter) generated during phacoemulsification in cadaveric human eyes with 2.2 mm and 2.75 mm corneal incisions, to assess whether hydroxypropyl methylcellulose (HPMC) reduces aerosol production, and to measure aerosol generation during individual steps of PPV. Methods Tests were performed on one model eye and two human cadaveric eyes. A printed optical particle spectrometer (POPS) was used to measure droplet aerosol generation during phacoemulsification through 2.2 mm and 2.75 mm main corneal incisions, with and without HPMC coating, and during predefined stages of 23-gauge PPV. Particle number concentration (PNC, particles cm⁻³) was recorded each second and summarised as mean PNC for each condition. Results In this small series, mean PNC during phacoemulsification without HPMC appeared to be higher with 2.75 mm incisions than with 2.2 mm incisions, and counts of particles >1 μm in diameter were also greater. Application of HPMC was associated with reduced aerosol counts. The maximum measured mean PNC without HPMC for 2.2 mm corneal incisions was 88 cm⁻³, which fell to 66 cm⁻³ with HPMC (p<0.05). For 2.75 mm incisions, the maximum measured mean PNC without HPMC was 493 cm⁻³, falling to 61 cm⁻³ with HPMC (p<0.05). No increase in droplet aerosol was detected during vitrectomy apart from during air infusion through a leaking trocar valve. Conclusion To our knowledge, this is the first study to use whole cadaveric human eyes in combination with a high-sensitivity optical particle spectrometer to quantify airborne particle number and size during phacoemulsification and PPV. In this model, droplet aerosol production during cataract surgery appeared lower with 2.2 mm incisions and with HPMC coating of the cornea. Droplet aerosols may be generated during vitrectomy when air infusion is delivered through a leaking trocar valve, highlighting the importance of port integrity.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2026-01-08
DOI
https://doi.org/10.7759/cureus.101100
Primary Topic
Retinal and Optic Conditions
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantification of Droplet Aerosol Generation During Phacoemulsification and Pars Plana Vitrectomy

B.A. Suresh, Inderpaul S. Sian, Edward N. Herbert, Daniel Partridge et al.
Cureus
Retinal and Optic Conditions
article

Quantification of Droplet Aerosol Generation During Phacoemulsification and Pars Plana Vitrectomy

B.A. Suresh, Inderpaul S. Sian, Edward N. Herbert, Daniel Partridge, Jonathan Park, Zixia Liu, James Haywood, Harikesh Kaneshayogan
article en

Abstract

Introduction Intraocular procedures such as phacoemulsification and pars plana vitrectomy (PPV) may generate fine droplet aerosols that are relevant to infection control, particularly in the context of SARS-CoV-2. Data on aerosol production during cataract and vitrectomy surgery, especially in human tissue and with different wound constructions, remain limited. This study used a high-sensitivity optical particle spectrometer to quantify droplet aerosols (0.12-8.00 μm in diameter) generated during phacoemulsification in cadaveric human eyes with 2.2 mm and 2.75 mm corneal incisions, to assess whether hydroxypropyl methylcellulose (HPMC) reduces aerosol production, and to measure aerosol generation during individual steps of PPV. Methods Tests were performed on one model eye and two human cadaveric eyes. A printed optical particle spectrometer (POPS) was used to measure droplet aerosol generation during phacoemulsification through 2.2 mm and 2.75 mm main corneal incisions, with and without HPMC coating, and during predefined stages of 23-gauge PPV. Particle number concentration (PNC, particles cm⁻³) was recorded each second and summarised as mean PNC for each condition. Results In this small series, mean PNC during phacoemulsification without HPMC appeared to be higher with 2.75 mm incisions than with 2.2 mm incisions, and counts of particles >1 μm in diameter were also greater. Application of HPMC was associated with reduced aerosol counts. The maximum measured mean PNC without HPMC for 2.2 mm corneal incisions was 88 cm⁻³, which fell to 66 cm⁻³ with HPMC (p<0.05). For 2.75 mm incisions, the maximum measured mean PNC without HPMC was 493 cm⁻³, falling to 61 cm⁻³ with HPMC (p<0.05). No increase in droplet aerosol was detected during vitrectomy apart from during air infusion through a leaking trocar valve. Conclusion To our knowledge, this is the first study to use whole cadaveric human eyes in combination with a high-sensitivity optical particle spectrometer to quantify airborne particle number and size during phacoemulsification and PPV. In this model, droplet aerosol production during cataract surgery appeared lower with 2.2 mm incisions and with HPMC coating of the cornea. Droplet aerosols may be generated during vitrectomy when air infusion is delivered through a leaking trocar valve, highlighting the importance of port integrity.

CureusVol. 18(1)
University of Exeter (GB), West Hertfordshire Hospitals NHS Trust (GB), Taunton & Somerset NHS Foundation Trust (GB), Somerset Partnership NHS Foundation Trust (GB)
Openalex Percentile: Top 93%
Retinal and Optic Conditions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.