Meloxicam Eluting 3D Printed 316L Stainless Steel Implants for Targeted Delivery in Bone Fixation Surgeries

Implant failures in orthopedic surgeries can occur due to inflammation, poor osteointegration, and biofilm formation. The local delivery of anti-inflammatory drugs is one of the potential solutions to address orthopedic implant failures caused by extensive inflammation, poor osteointegration, and biofilm formation. This study utilized a simple spray coating technique to deposit multilayer coatings of the anti-inflammatory drug meloxicam and PLGA on 3D printed 316L stainless steel implants. The implants were evaluated for their drug content, drug-polymer miscibility, static contact angle, corrosion resistance, in vitro release, cell adhesion, cell proliferation, and bacterial adhesion studies. The coatings aimed to improve osteointegration and reduce biofilm formation. The drug release studies demonstrated an initial burst release accompanied by sustained release for more than 30 days. The meloxicam-PLGA coated implants showed higher resistance to pitting corrosion, improved adhesion, and proliferation of human U2OS cells in comparison to uncoated implants. In addition, results from cell cytotoxicity studies confirmed that all the coatings are biocompatible and safe for in vivo application. The meloxicam-PLGA coated implants were also found to have significantly lower bacterial adhesion and biofilm formation compared to uncoated implants for both S. aureus (p < 0.01) and S. pseudintermedius (p < 0.01). The multilayer coatings developed in this study have the potential to improve adhesion at the implant-bone interface and thus might prevent implant rejections in patients undergoing orthopedic surgery. Moreover, this method can be applied to other drugs and polymers to address the issues related to implant failure, pain management, and surgical site infections.

Authors

Institutions

Publication Details

Journal
AAPS PharmSciTech
Published
2026-01-08
DOI
https://doi.org/10.1208/s12249-025-03294-2
Primary Topic
Bone Tissue Engineering Materials
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Meloxicam Eluting 3D Printed 316L Stainless Steel Implants for Targeted Delivery in Bone Fixation Surgeries

Nur Mita, Chu Zhang, Robert D. Arnold, Peter Panizzi et al.
AAPS PharmSciTech
Bone Tissue Engineering Materials
article

Meloxicam Eluting 3D Printed 316L Stainless Steel Implants for Targeted Delivery in Bone Fixation Surgeries

Nur Mita, Chu Zhang, Robert D. Arnold, Peter Panizzi, Nima Shamsaei, Amal Kaddoumi, Manjusha Annaji, Seung-Jong Lee, Oladiran Fasina, Ishwor Poudel, R. Jayachandra Babu, Byron Farnum, Humaira Yeasmin
article en

Abstract

Implant failures in orthopedic surgeries can occur due to inflammation, poor osteointegration, and biofilm formation. The local delivery of anti-inflammatory drugs is one of the potential solutions to address orthopedic implant failures caused by extensive inflammation, poor osteointegration, and biofilm formation. This study utilized a simple spray coating technique to deposit multilayer coatings of the anti-inflammatory drug meloxicam and PLGA on 3D printed 316L stainless steel implants. The implants were evaluated for their drug content, drug-polymer miscibility, static contact angle, corrosion resistance, in vitro release, cell adhesion, cell proliferation, and bacterial adhesion studies. The coatings aimed to improve osteointegration and reduce biofilm formation. The drug release studies demonstrated an initial burst release accompanied by sustained release for more than 30 days. The meloxicam-PLGA coated implants showed higher resistance to pitting corrosion, improved adhesion, and proliferation of human U2OS cells in comparison to uncoated implants. In addition, results from cell cytotoxicity studies confirmed that all the coatings are biocompatible and safe for in vivo application. The meloxicam-PLGA coated implants were also found to have significantly lower bacterial adhesion and biofilm formation compared to uncoated implants for both S. aureus (p < 0.01) and S. pseudintermedius (p < 0.01). The multilayer coatings developed in this study have the potential to improve adhesion at the implant-bone interface and thus might prevent implant rejections in patients undergoing orthopedic surgery. Moreover, this method can be applied to other drugs and polymers to address the issues related to implant failure, pain management, and surgical site infections.

AAPS PharmSciTechVol. 27(1)
Mulawarman University (ID), Auburn University (US)
Auburn University
Openalex Percentile: Top 93%
Bone Tissue Engineering Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.