First-in-human experience for cardiac arrhythmia mapping using a novel ultra-high–density globe-shaped catheter from the multicenter COSMOS study

<h2>Abstract</h2><h3>Background</h3> A novel ultra-high resolution mapping system (Clarysense, Biosense Webster, Inc.) consists of a 100-electrode deflectable bidirectional basket-shaped high-density mapping catheter, incorporating a central TRUEref electrode, integrated with the CARTO 3 System. <h3>Objective</h3> To assess the clinical safety and performance of the novel system for mapping in complex atrial and ventricular arrhythmias. <h3>Methods</h3> This prospective, single-arm, multicenter study included patients undergoing catheter mapping and ablation of atrial and ventricular arrhythmias. Mapping was performed with the study catheter and participants were ablated per investigator's standard of care. The primary effectiveness endpoint was completion of preablation electroanatomical mapping without resorting to a nonstudy catheter. The primary safety endpoint was incidence of device-related serious adverse events (SAEs) within 7 days. Physician feedback on catheter performance was collected via a 7-point Likert scale. <h3>Results</h3> 40 participants (mean age 58.0±15.73 years, 62.5% male, 30 with atrial arrhythmias, 10 with ventricular arrhythmias) underwent mapping with the study catheter. The primary effectiveness endpoint was achieved in all participants; ≥1 area of interest for mappable rhythms was identified in 23/30 atrial arrhythmia participants. One SAE of transient complete atrioventricular block was reported in a persistent atrial fibrillation patient during preablation mapping, with full recovery. Physician feedback indicated the device met or exceeded expectations for signal quality; most responders rated highly on bipolar signal quality in atria and noise encountered. <h3>Conclusion</h3> In this first-in-human study, the novel mapping system improved high-density mapping in complex arrhythmias with high-quality signals and map resolution. The catheter exceeded operators' expectations in signal fidelity.

Authors

Institutions

Publication Details

Journal
Heart Rhythm O2
Published
2026-01-09
DOI
https://doi.org/10.1016/j.hroo.2025.11.029
Primary Topic
Cardiac Arrhythmias and Treatments
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

First-in-human experience for cardiac arrhythmia mapping using a novel ultra-high–density globe-shaped catheter from the multicenter COSMOS study

T. De Potter, Toni Brešković, Hiroshi Nakagawa, Alexandre Almorad et al.
Heart Rhythm O2
Cardiac Arrhythmias and Treatments
article

First-in-human experience for cardiac arrhythmia mapping using a novel ultra-high–density globe-shaped catheter from the multicenter COSMOS study

T. De Potter, Toni Brešković, Hiroshi Nakagawa, Alexandre Almorad, Massimo Grimaldi, Antonio di Monaco, Gian Battista Chierchia, Carlo de Asmundis, Ante Anic, Moussa Mansour
article en

Abstract

<h2>Abstract</h2><h3>Background</h3> A novel ultra-high resolution mapping system (Clarysense, Biosense Webster, Inc.) consists of a 100-electrode deflectable bidirectional basket-shaped high-density mapping catheter, incorporating a central TRUEref electrode, integrated with the CARTO 3 System. <h3>Objective</h3> To assess the clinical safety and performance of the novel system for mapping in complex atrial and ventricular arrhythmias. <h3>Methods</h3> This prospective, single-arm, multicenter study included patients undergoing catheter mapping and ablation of atrial and ventricular arrhythmias. Mapping was performed with the study catheter and participants were ablated per investigator's standard of care. The primary effectiveness endpoint was completion of preablation electroanatomical mapping without resorting to a nonstudy catheter. The primary safety endpoint was incidence of device-related serious adverse events (SAEs) within 7 days. Physician feedback on catheter performance was collected via a 7-point Likert scale. <h3>Results</h3> 40 participants (mean age 58.0±15.73 years, 62.5% male, 30 with atrial arrhythmias, 10 with ventricular arrhythmias) underwent mapping with the study catheter. The primary effectiveness endpoint was achieved in all participants; ≥1 area of interest for mappable rhythms was identified in 23/30 atrial arrhythmia participants. One SAE of transient complete atrioventricular block was reported in a persistent atrial fibrillation patient during preablation mapping, with full recovery. Physician feedback indicated the device met or exceeded expectations for signal quality; most responders rated highly on bipolar signal quality in atria and noise encountered. <h3>Conclusion</h3> In this first-in-human study, the novel mapping system improved high-density mapping in complex arrhythmias with high-quality signals and map resolution. The catheter exceeded operators' expectations in signal fidelity.

Heart Rhythm O2Vol. 7(3)
Cleveland Clinic (US), Massachusetts General Hospital (US), Onze Lieve Vrouwziekenhuis Hospital (BE), Universitair Ziekenhuis Brussel (BE), Ospedale Generale Regionale Francesco Miulli (IT), University of Split (HR)
Biosense Webster
Openalex Percentile: Top 94%
Cardiac Arrhythmias and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.