Performance of TiO

This study examines the performance of TiO2 nanolubricant at concentrations of 0, 0.2, and 0.4 g/L in a slightly modified refrigeration system, tested with door openings of 30, 60, 120, 180, 240, and 300 seconds. The system was charged with 30 g of either LPG or R600a refrigerant, combined with the specified TiO2 concentrations. Monitoring involved a digital pressure gauge, K-type thermocouples, and a wattmeter to assess energy behaviour under closed and open-door conditions. Key performance metrics included closed-door pull-down time, open-door air infiltration heat rate and load, power consumption, compressor power, and recovery rate. All tests complied with ISO 8187, achieving a minimum evaporator air temperature of -3°C within one hour of continuous operation. For both R600a and LPG refrigerants, air infiltration heat rate and load decreased from 0.02162 m3/s and 2.4365 kW at 30 seconds to 0.02085 m3/s and 0.602 kW for door openings of 60 to 300 seconds. Conversely, recovery rate, energy consumption, and compressor power increased with longer door openings. Adding TiO2 nanolubricant reduced recovery rate by 1.08%65.8% for R600a and 2.12% - 85% for LPG, compressor power by 4.14%43.01% for R600a and 5.92% -30.92% for LPG, and energy consumption by 13.33% - 66.67% for R600a and 5.88% - 80% for LPG. Overall, TiO2 nanolubricants substantially mitigated the impact of air infiltration into the evaporator cabinet.

Authors

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2026-01-07
DOI
https://doi.org/10.1051/e3sconf/202668402001/pdf
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance of TiO

Damola S. Adelekan, Olayinka S. Ohunakin, Babu Sena Paul, Tien Chien Jen
Springer Link (Chiba Institute of Technology)
Refrigeration and Air Conditioning Technologies
article

Performance of TiO

Damola S. Adelekan, Olayinka S. Ohunakin, Babu Sena Paul, Tien Chien Jen
article en

Abstract

This study examines the performance of TiO2 nanolubricant at concentrations of 0, 0.2, and 0.4 g/L in a slightly modified refrigeration system, tested with door openings of 30, 60, 120, 180, 240, and 300 seconds. The system was charged with 30 g of either LPG or R600a refrigerant, combined with the specified TiO2 concentrations. Monitoring involved a digital pressure gauge, K-type thermocouples, and a wattmeter to assess energy behaviour under closed and open-door conditions. Key performance metrics included closed-door pull-down time, open-door air infiltration heat rate and load, power consumption, compressor power, and recovery rate. All tests complied with ISO 8187, achieving a minimum evaporator air temperature of -3°C within one hour of continuous operation. For both R600a and LPG refrigerants, air infiltration heat rate and load decreased from 0.02162 m3/s and 2.4365 kW at 30 seconds to 0.02085 m3/s and 0.602 kW for door openings of 60 to 300 seconds. Conversely, recovery rate, energy consumption, and compressor power increased with longer door openings. Adding TiO2 nanolubricant reduced recovery rate by 1.08%65.8% for R600a and 2.12% - 85% for LPG, compressor power by 4.14%43.01% for R600a and 5.92% -30.92% for LPG, and energy consumption by 13.33% - 66.67% for R600a and 5.88% - 80% for LPG. Overall, TiO2 nanolubricants substantially mitigated the impact of air infiltration into the evaporator cabinet.

Springer Link (Chiba Institute of Technology)
Covenant University, University of Johannesburg, Covenant University Centre for Research, Innovation and Discovery
Affordable and clean energy
Openalex Percentile: Top 93%
Refrigeration and Air Conditioning Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.