Mechanisms of Trifecta Valve Failure and Contemporary Approaches to Reintervention: Perceval vs Valve-in-Valve Transcatheter Aortic Valve Implantation
We recommend that patients following Trifecta implantation with preoperative impaired kidneys, postoperative low effective orifice area (EOA) indexes, and prosthesis-patient mismatch be closely followed with echocardiograms to detect a possible Trifecta failure. Replacing a failed Trifecta valve with a sutureless Perceval could be an excellent option to approach a pre-existing small native annulus. Valve-in-valve transcatheter aortic valve implantation is a less favourable option due to the risk of a reduced EOA, though it may still be considered in selected patients with larger annuli.
Authors
- Mohammad Azari
- Sumit Yadav (ORCID: https://orcid.org/0000-0002-2434-7995)
Institutions
- John Hunter Hospital (AU)
- Liverpool Hospital (AU)
- Mater Private Hospital (AU)
- James Cook University (AU)
Publication Details
- Journal
- Interdisciplinary CardioVascular and Thoracic Surgery
- Published
- 2026-01-01
- DOI
- https://doi.org/10.1093/icvts/ivaf234
- Primary Topic
- Cardiac Valve Diseases and Treatments
- Type
- article
- Field-Weighted Citation Impact
- 0.00