Simultaneous Multiparameter Detection with Organic Electrochemical Transistors-Based Biosensors

We present a methodology that enhances the analytical performance of organic electrochemical transistors (OECTs) by continuously cycling the devices through gate potential sweeps during sensing experiments. This continuous cycling methodology (CCM) enables real-time acquisition of full transfer curves, allowing simultaneous monitoring of multiple characteristic parameters. We show that the simultaneous temporal evolution of several OECT response parameters (threshold voltage (VTH), maximum transconductance (gmax), and maximum transconductance potential (VG,gmax)) provides highly sensitive descriptors for detecting pH changes and macromolecule adsorption on OECTs based on polyaniline (PANI) and poly(3,4-ethylenedioxythiophene) (PEDOT) channels. Moreover, the method allows reconstruction of IDS–t (drain–source current vs. time) profiles at any selected gate potential, enabling the identification of optimal gate voltage (VG) values for maximizing sensitivity. This represents a substantial improvement over traditional measurements at fixed VG, which may suffer from reduced sensitivity and parasitic reactions associated with gate polarization. Moreover, the expanded set of parameters obtained with the CCM provides deeper insight into the physicochemical processes occurring at both gate and channel electrodes. We demonstrate its applicability in monitoring polyelectrolyte and enzyme adsorption, and detecting urea and glucose through enzyme-mediated reactions. Owing to its versatility and the richness of the information it provides, the CCM constitutes a significant advance for the development and optimization of OECT-based sensing platforms.

Authors

Institutions

Publication Details

Journal
Chemosensors
Published
2026-01-09
DOI
https://doi.org/10.3390/chemosensors14010022
Citations
2
Primary Topic
Conducting polymers and applications
Type
article
Field-Weighted Citation Impact
38.85

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simultaneous Multiparameter Detection with Organic Electrochemical Transistors-Based Biosensors

Marjorie Montero-Jiménez, Omar Azzaroni, Jael R. Neyra Recky, Waldemar A. Marmisollé et al.
2 citations
Chemosensors
Conducting polymers and applications
38.85
article

Simultaneous Multiparameter Detection with Organic Electrochemical Transistors-Based Biosensors

Marjorie Montero-Jiménez, Omar Azzaroni, Jael R. Neyra Recky, Waldemar A. Marmisollé, Juliana Scotto
article en
2 citations

Abstract

We present a methodology that enhances the analytical performance of organic electrochemical transistors (OECTs) by continuously cycling the devices through gate potential sweeps during sensing experiments. This continuous cycling methodology (CCM) enables real-time acquisition of full transfer curves, allowing simultaneous monitoring of multiple characteristic parameters. We show that the simultaneous temporal evolution of several OECT response parameters (threshold voltage (VTH), maximum transconductance (gmax), and maximum transconductance potential (VG,gmax)) provides highly sensitive descriptors for detecting pH changes and macromolecule adsorption on OECTs based on polyaniline (PANI) and poly(3,4-ethylenedioxythiophene) (PEDOT) channels. Moreover, the method allows reconstruction of IDS–t (drain–source current vs. time) profiles at any selected gate potential, enabling the identification of optimal gate voltage (VG) values for maximizing sensitivity. This represents a substantial improvement over traditional measurements at fixed VG, which may suffer from reduced sensitivity and parasitic reactions associated with gate polarization. Moreover, the expanded set of parameters obtained with the CCM provides deeper insight into the physicochemical processes occurring at both gate and channel electrodes. We demonstrate its applicability in monitoring polyelectrolyte and enzyme adsorption, and detecting urea and glucose through enzyme-mediated reactions. Owing to its versatility and the richness of the information it provides, the CCM constitutes a significant advance for the development and optimization of OECT-based sensing platforms.

ChemosensorsVol. 14(1)
Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas (AR)
Consejo Nacional de Investigaciones Científicas y Técnicas, Universidad Nacional de La Plata, Agencia Nacional de Promoción Científica y Tecnológica
Openalex Percentile: Top 1%
Conducting polymers and applications
38.85
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Simultaneous Multiparameter Detection with Organic Electrochemical Transistors-Based Biosensors — Marjorie Montero-Jiménez, Omar Azzaroni, et al. · Chemosensors (2026) | TGRS Research Map | TGRS