Performance of on-site flow cytometry for near-real-time microbiological analysis of alpine karst drinking water resources

Abstract This study presents the first rigorous, multi-parameter evaluation of near-real-time flow cytometry (FCM) for automated on-site monitoring at a model alpine karst spring used as a drinking water resource. We tested automated FCM for its capacity to indicate microbial cell inputs from the catchment surface (SRI) and to indirectly indicate diffuse faecal contamination (DFC). A nested 10-year study design combined low-frequency monitoring with high-frequency event sampling. The instruments tested in the study performed well under challenging field conditions and reliably quantified microbial cells, as validated against established methods. FCM parameters robustly detected SRI and, indirectly, DFC, in a catchment with diffuse animal faecal contamination sources. The same performance was observed for the online physico-chemical parameters UV254 and turbidity. The combination of these biotic and abiotic indicators outperformed single parameters in early warning analyses, demonstrating their potential for water safety planning by enabling timely and specific responses. The various aspects of the automated on-site monitoring devices used are discussed in detail. While automated FCM already supports the indirect detection of diffuse faecal pollution, further technical advances are necessary to extend its scope toward the specific and sensitive detection of faecal contamination.

Authors

Institutions

Publication Details

Journal
npj Clean Water
Published
2026-01-09
DOI
https://doi.org/10.1038/s41545-025-00536-5
Primary Topic
Fecal contamination and water quality
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance of on-site flow cytometry for near-real-time microbiological analysis of alpine karst drinking water resources

Anna Polz, Sandra Peer, Rita Linke, Adrian Shajkofci et al.
npj Clean Water
Fecal contamination and water quality
article

Performance of on-site flow cytometry for near-real-time microbiological analysis of alpine karst drinking water resources

Anna Polz, Sandra Peer, Rita Linke, Adrian Shajkofci, Lena Campostrini, Katalin Demeter, Stefan Jakwerth, Julia Derx, Alexander K. T. Kirschner, Margaret E. Stevenson, Andreas H. Farnleitner, Luigino Grasso
article en

Abstract

Abstract This study presents the first rigorous, multi-parameter evaluation of near-real-time flow cytometry (FCM) for automated on-site monitoring at a model alpine karst spring used as a drinking water resource. We tested automated FCM for its capacity to indicate microbial cell inputs from the catchment surface (SRI) and to indirectly indicate diffuse faecal contamination (DFC). A nested 10-year study design combined low-frequency monitoring with high-frequency event sampling. The instruments tested in the study performed well under challenging field conditions and reliably quantified microbial cells, as validated against established methods. FCM parameters robustly detected SRI and, indirectly, DFC, in a catchment with diffuse animal faecal contamination sources. The same performance was observed for the online physico-chemical parameters UV254 and turbidity. The combination of these biotic and abiotic indicators outperformed single parameters in early warning analyses, demonstrating their potential for water safety planning by enabling timely and specific responses. The various aspects of the automated on-site monitoring devices used are discussed in detail. While automated FCM already supports the indirect detection of diffuse faecal pollution, further technical advances are necessary to extend its scope toward the specific and sensitive detection of faecal contamination.

npj Clean WaterVol. 9(1)
TU Wien (AT), St Anna Children's Hospital (AT), Interuniversity Cooperation Centre Water & Health (AT), SA Technologies (United States) (US), Karl Landsteiner University of Health Sciences (AT), Medical University of Vienna (AT)
Technische Universität Wien, Technische Universität Wien Bibliothek, Eurostars
Clean water and sanitation
Openalex Percentile: Top 94%
Fecal contamination and water quality
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.