Biomechanical Evaluation of a Novel Six Strands, Non-locking Flexor Tendon Repair Technique

<b>Background:</b> We designed a new non-locking six-strand suture technique (Li-Wee) as an evolution of our previous work. The aim of this study is to biomechanically compare repairs using this technique with FiberWire<sup>®</sup> 4-0 versus Prolene<sup>®</sup> 4-0. <b>Methods:</b> Thirty porcine flexor tendons were harvested for the experiments. A transverse cut was made in the middle of the tendons to allow for tendon repair. Repairs were made equally by using the Li-Wee technique with FiberWire<sup>®</sup> 4-0 and Prolene<sup>®</sup> 4-0. The ultimate tensile strength (UTS), load to 2 mm gap force, stiffness and repair times were measured under static testing. Furthermore, cyclic testing was performed on five specimens with the circumferential epitendinous suture from each repair group to evaluate their gap formation under cyclic loadings and final UTS. <b>Results:</b> The mean UTS of repairs using FiberWire<sup>®</sup> was 81.3 ± 10.3 N while repairs done with Prolene<sup>®</sup> was 66.7 ± 8.3 N under static testing, and 98.7 ± 4.9 N for repairs using FiberWire<sup>®</sup> and 68.3 ± 10.4 N for repairs using Prolene<sup>®</sup> under cyclic testing. Comparing FiberWire<sup>®</sup> and Prolene<sup>®</sup> repairs, the load to 2 mm gap force was 37.6 ± 8.4 N and 31.0 ± 10.9 N; stiffness was 6.5 ± 0.9 N/m and 8.1 ± 1.0 N/m; repair times were 466 ± 45 s and 465 ± 62 s, respectively. A statistically significant difference was found between groups for UTS under both static and cyclic testing, as well as stiffness. <b>Conclusions:</b> This study has shown that six-strand non-locking Li-Wee flexor tendon repair using FiberWire<sup>®</sup> offers satisfactory repair strength, adequate stiffness and 2 mm gap force.

Authors

Institutions

Publication Details

Journal
The Journal of Hand Surgery (Asian-Pacific Volume)
Published
2026-01-05
DOI
https://doi.org/10.1142/s242483552650013x
Primary Topic
Orthopedic Surgery and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Biomechanical Evaluation of a Novel Six Strands, Non-locking Flexor Tendon Repair Technique

Jiayi Li, Naufal Bin Shahri, JIE REI Wee, YOKE-RUNG Wong et al.
The Journal of Hand Surgery (Asian-Pacific Volume)
Orthopedic Surgery and Rehabilitation
article

Biomechanical Evaluation of a Novel Six Strands, Non-locking Flexor Tendon Repair Technique

Jiayi Li, Naufal Bin Shahri, JIE REI Wee, YOKE-RUNG Wong, FANG Li
article en

Abstract

<b>Background:</b> We designed a new non-locking six-strand suture technique (Li-Wee) as an evolution of our previous work. The aim of this study is to biomechanically compare repairs using this technique with FiberWire<sup>®</sup> 4-0 versus Prolene<sup>®</sup> 4-0. <b>Methods:</b> Thirty porcine flexor tendons were harvested for the experiments. A transverse cut was made in the middle of the tendons to allow for tendon repair. Repairs were made equally by using the Li-Wee technique with FiberWire<sup>®</sup> 4-0 and Prolene<sup>®</sup> 4-0. The ultimate tensile strength (UTS), load to 2 mm gap force, stiffness and repair times were measured under static testing. Furthermore, cyclic testing was performed on five specimens with the circumferential epitendinous suture from each repair group to evaluate their gap formation under cyclic loadings and final UTS. <b>Results:</b> The mean UTS of repairs using FiberWire<sup>®</sup> was 81.3 ± 10.3 N while repairs done with Prolene<sup>®</sup> was 66.7 ± 8.3 N under static testing, and 98.7 ± 4.9 N for repairs using FiberWire<sup>®</sup> and 68.3 ± 10.4 N for repairs using Prolene<sup>®</sup> under cyclic testing. Comparing FiberWire<sup>®</sup> and Prolene<sup>®</sup> repairs, the load to 2 mm gap force was 37.6 ± 8.4 N and 31.0 ± 10.9 N; stiffness was 6.5 ± 0.9 N/m and 8.1 ± 1.0 N/m; repair times were 466 ± 45 s and 465 ± 62 s, respectively. A statistically significant difference was found between groups for UTS under both static and cyclic testing, as well as stiffness. <b>Conclusions:</b> This study has shown that six-strand non-locking Li-Wee flexor tendon repair using FiberWire<sup>®</sup> offers satisfactory repair strength, adequate stiffness and 2 mm gap force.

The Journal of Hand Surgery (Asian-Pacific Volume)Vol. 31(01)
Singapore General Hospital (SG), Raffles Institution (SG)
Openalex Percentile: Top 94%
Orthopedic Surgery and Rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Biomechanical Evaluation of a Novel Six Strands, Non-locking Flexor Tendon Repair Technique — Jiayi Li, Naufal Bin Shahri, et al. · The Journal of Hand Surgery (Asian-Pacific Volume) (2026) | TGRS Research Map | TGRS