Molecularly imprinted film based on chitosan-GQDs using citric acid as a crosslinker for creatinine adsorption and detection by FTIR-ATR

A molecularly imprinted polymer (MIP) film based on 3.5% w / v chitosan and graphene quantum dots (GQDs), crosslinked with citric acid (0.25% w / v ), was developed for the selective adsorption and detection of creatinine. Citric acid functioned both as a green crosslinker and as the GQD precursor, enabling an environmentally friendly fabrication route. The structural and morphological features of the MIP film were confirmed using AFM, SEM, FTIR-ATR, and UV–vis spectroscopy, while complete template removal was achieved through DI-water washing assisted by ultrasonication. Kinetic studies revealed rapid adsorption behavior, reaching equilibrium within 40–60 min, with a maximum adsorption capacity (Qₑ) of 12.5 mg g −1 . The MIP exhibited optimal binding at physiological conditions (pH 7, 37 °C), governed by synergistic electrostatic interactions, hydrogen bonding, and π–π interactions. Quantification based on the FTIR-ATR, ΔAbsorbance at 1375 cm −1 demonstrated high analytical sensitivity, achieving a limit of detection of 4.2 nM and a broad linear range from 0.1 nM to 10 μM (R 2 = 0.9873). The sensor showed strong selectivity against common interferents (urea, glucose, NHS), maintaining accurate responses even at 10-fold excess concentrations. Application to synthetic urine yielded a recovery of 90.3% using the standard addition method. • Eco-friendly MIP film was prepared using chitosan, GQDs, and citric acid. • The film shows high selectivity for creatinine over common biological compounds. • Nanomolar-level sensitivity was achieved with fast adsorption at neutral pH. • The film accurately detects creatinine in synthetic urine samples. • A promising biosensor for improving clinical creatinine detection methods.

Authors

Institutions

Publication Details

Journal
Results in Chemistry
Published
2026-01-08
DOI
https://doi.org/10.1016/j.rechem.2026.103045
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Molecularly imprinted film based on chitosan-GQDs using citric acid as a crosslinker for creatinine adsorption and detection by FTIR-ATR

Nutthaya Butwong, Pimpanitpa Kunthadong, Siriboon Mukdasai, John H. T. Luong et al.
Results in Chemistry
Electrochemical sensors and biosensors
article

Molecularly imprinted film based on chitosan-GQDs using citric acid as a crosslinker for creatinine adsorption and detection by FTIR-ATR

Nutthaya Butwong, Pimpanitpa Kunthadong, Siriboon Mukdasai, John H. T. Luong, Thitima Thatujirangkul
article en

Abstract

A molecularly imprinted polymer (MIP) film based on 3.5% w / v chitosan and graphene quantum dots (GQDs), crosslinked with citric acid (0.25% w / v ), was developed for the selective adsorption and detection of creatinine. Citric acid functioned both as a green crosslinker and as the GQD precursor, enabling an environmentally friendly fabrication route. The structural and morphological features of the MIP film were confirmed using AFM, SEM, FTIR-ATR, and UV–vis spectroscopy, while complete template removal was achieved through DI-water washing assisted by ultrasonication. Kinetic studies revealed rapid adsorption behavior, reaching equilibrium within 40–60 min, with a maximum adsorption capacity (Qₑ) of 12.5 mg g −1 . The MIP exhibited optimal binding at physiological conditions (pH 7, 37 °C), governed by synergistic electrostatic interactions, hydrogen bonding, and π–π interactions. Quantification based on the FTIR-ATR, ΔAbsorbance at 1375 cm −1 demonstrated high analytical sensitivity, achieving a limit of detection of 4.2 nM and a broad linear range from 0.1 nM to 10 μM (R 2 = 0.9873). The sensor showed strong selectivity against common interferents (urea, glucose, NHS), maintaining accurate responses even at 10-fold excess concentrations. Application to synthetic urine yielded a recovery of 90.3% using the standard addition method. • Eco-friendly MIP film was prepared using chitosan, GQDs, and citric acid. • The film shows high selectivity for creatinine over common biological compounds. • Nanomolar-level sensitivity was achieved with fast adsorption at neutral pH. • The film accurately detects creatinine in synthetic urine samples. • A promising biosensor for improving clinical creatinine detection methods.

Results in ChemistryVol. 20
Rajamangala University of Technology Isan (TH), Khon Kaen University (TH), University College Cork (IE)
Life in Land
Openalex Percentile: Top 94%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.