Application of the Chaotic System–Based Error Trace Diagrams for Partial Discharge Feature Extraction

ABSTRACT This study established four models representing common defect types in 25‐kV cross‐linked polyethylene power cable joints and analysed partial discharge (PD) signals associated with such defects. An acoustic emission sensor was used to measure acoustic signals induced by the PD phenomenon in the power cable joints. A chaotic synchronisation system was applied to analyse dynamic errors associated with the signals. Motion trajectories were calculated using the master and slave systems in the Chen‐Lee chaotic system and then plotted as three‐dimensional error trace diagrams for each of the four models. Two chaotic gravity distances were obtained as features and a backpropagation neural network algorithm was used for cable joint pattern recognition. Furthermore, acoustic signals were measured from 160 sets of cable joints and random white noise was added to test the robustness of the feature extraction algorithm against noise. This study also evaluated the use of fractal dimensions for extracting features from 3D PD patterns. The results confirmed that the proposed method achieved high accuracy, was straightforward to implement and effectively distinguished between different cable joint models.

Authors

Institutions

Publication Details

Journal
IET Science Measurement & Technology
Published
2026-01-01
DOI
https://doi.org/10.1049/smt2.70041
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Application of the Chaotic System–Based Error Trace Diagrams for Partial Discharge Feature Extraction

Feng‐Chang Gu, Sen‐Fu Chan
IET Science Measurement & Technology
High voltage insulation and dielectric phenomena
article

Application of the Chaotic System–Based Error Trace Diagrams for Partial Discharge Feature Extraction

Feng‐Chang Gu, Sen‐Fu Chan
article en

Abstract

ABSTRACT This study established four models representing common defect types in 25‐kV cross‐linked polyethylene power cable joints and analysed partial discharge (PD) signals associated with such defects. An acoustic emission sensor was used to measure acoustic signals induced by the PD phenomenon in the power cable joints. A chaotic synchronisation system was applied to analyse dynamic errors associated with the signals. Motion trajectories were calculated using the master and slave systems in the Chen‐Lee chaotic system and then plotted as three‐dimensional error trace diagrams for each of the four models. Two chaotic gravity distances were obtained as features and a backpropagation neural network algorithm was used for cable joint pattern recognition. Furthermore, acoustic signals were measured from 160 sets of cable joints and random white noise was added to test the robustness of the feature extraction algorithm against noise. This study also evaluated the use of fractal dimensions for extracting features from 3D PD patterns. The results confirmed that the proposed method achieved high accuracy, was straightforward to implement and effectively distinguished between different cable joint models.

IET Science Measurement & TechnologyVol. 20(1)
National Chin-Yi University of Technology (TW)
National Science and Technology Council
Openalex Percentile: Top 93%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines