Validated HPLC Methodology for Pregabalin Quantification in Human Urine Using 1-Fluoro-2,4-dinitrobenzene Derivatization

Pregabalin (PGB) is a synthetic drug used for the treatment of central nervous system disorders and neuropathic pain. PGB is metabolized to N-Methyl pregabalin while the rest is excreted virtually unchanged in the urine. Numerous analytical techniques for measuring pregabalin have been documented. This study aimed to validate a simple, sensitive, and accurate method for PGB quantification in human urine using the HPLC technique with 1-Fluoro-2, 4-dinitrobenzene used as a derivatizing agent. One hundred and twenty urine samples were analyzed by a reversed-phase (C18) column and a mixture of acetonitrile and 50 mM KH2PO4 (pH 2.5) (60:40, v/v) as mobile phase and the flow rate was 1 ml/min and the UV detector wavelength was set to 360nm. The procedure was linear within the 10-1000 μg/ml range of PGB in urine (r > 0.99). Intraday and interday RSD precision values fell between 2.8% and 5.9%. 2.5 and 1.5 μg/ml, respectively, were determined to be the method's limits of quantification and detection. The recovery (90.8%) and statistical characteristics show that the suggested method has excellent accuracy and precision. The method is accurate, precise, reproducible, and specific, and it can be applied to regular examinations of pregabalin in urine samples.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-12-01
Primary Topic
Forensic Toxicology and Drug Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validated HPLC Methodology for Pregabalin Quantification in Human Urine Using 1-Fluoro-2,4-dinitrobenzene Derivatization

SHILAP Revista de lepidopterología
Forensic Toxicology and Drug Analysis
article

Validated HPLC Methodology for Pregabalin Quantification in Human Urine Using 1-Fluoro-2,4-dinitrobenzene Derivatization

article en

Abstract

Pregabalin (PGB) is a synthetic drug used for the treatment of central nervous system disorders and neuropathic pain. PGB is metabolized to N-Methyl pregabalin while the rest is excreted virtually unchanged in the urine. Numerous analytical techniques for measuring pregabalin have been documented. This study aimed to validate a simple, sensitive, and accurate method for PGB quantification in human urine using the HPLC technique with 1-Fluoro-2, 4-dinitrobenzene used as a derivatizing agent. One hundred and twenty urine samples were analyzed by a reversed-phase (C18) column and a mixture of acetonitrile and 50 mM KH2PO4 (pH 2.5) (60:40, v/v) as mobile phase and the flow rate was 1 ml/min and the UV detector wavelength was set to 360nm. The procedure was linear within the 10-1000 μg/ml range of PGB in urine (r > 0.99). Intraday and interday RSD precision values fell between 2.8% and 5.9%. 2.5 and 1.5 μg/ml, respectively, were determined to be the method's limits of quantification and detection. The recovery (90.8%) and statistical characteristics show that the suggested method has excellent accuracy and precision. The method is accurate, precise, reproducible, and specific, and it can be applied to regular examinations of pregabalin in urine samples.

SHILAP Revista de lepidopterología
Ain Shams University Hospital (EG)
Good health and well-being
Openalex Percentile: Top 50%
Forensic Toxicology and Drug Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.