Biomechanical and Functional Response of <scp>3D</scp> Printed Materials and Silicone Elastomers Compared to Human Aortic Tissues

Synthetic materials that mimic the biomechanical and functional response of vascular tissues have applications in medical device testing and surgical training. 3D printing has emerged as a key technology to build complex patient-specific anatomical models with multiple materials to mimic a range of tissue types. However, the capability of 3D printing materials to replicate the mechanical and functional response of native vascular tissues is not clear. The primary goal of this study was to compare the biomechanical response of synthetic 3D printed and polymeric materials against native aortic tissues. Toward this goal, tissue samples from the inner and outer curvature of ascending aorta were obtained from 20 healthy aortic donors. Bi-axial testing was performed on native aortic tissues, Stratasys TissueMatrix series, and silicone samples (Gluck Medical, Soul, Korea). Adult and pediatric aortic phantom with semilunar valves were 3D printed with TissueMatrix materials to perform functional testing. Our findings demonstrated that the elastic modulus of the 3D printed TissueMatrix materials was significantly higher than native aortic tissues at low tangent and high tangent modulus while no significant differences were found for silicone. Mean transvalvular pressure gradients in 3D printed aortic phantoms ranged from 3.5 mmHg to 6 mmHg for Reynolds number ranging from 2000 to 3500, respectively and increased to 25 mmHg at Reynolds number of 7000. 3D printed valves remained intact without fracture or tear even at high Reynolds number. Our work highlights that 3D printed materials are stiffer compared to native tissues with functional responses that resemble stiff native valves. Future work should focus on developing more compliant material mixtures that could ultimately support in device simulations and procedural planning.

Authors

Institutions

Publication Details

Journal
Journal of Biomedical Materials Research Part A
Published
2026-01-01
DOI
https://doi.org/10.1002/jbma.70022
Primary Topic
Soft Robotics and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Biomechanical and Functional Response of 3D Printed Materials and Silicone Elastomers Compared to Human Aortic Tissues

Daniella Eliathamby, Craig A. Simmons, Vivian Tan, Jennifer Chung et al.
Journal of Biomedical Materials Research Part A
Soft Robotics and Applications
article

Biomechanical and Functional Response of 3D Printed Materials and Silicone Elastomers Compared to Human Aortic Tissues

Daniella Eliathamby, Craig A. Simmons, Vivian Tan, Jennifer Chung, M. Owais Khan
article en

Abstract

Synthetic materials that mimic the biomechanical and functional response of vascular tissues have applications in medical device testing and surgical training. 3D printing has emerged as a key technology to build complex patient-specific anatomical models with multiple materials to mimic a range of tissue types. However, the capability of 3D printing materials to replicate the mechanical and functional response of native vascular tissues is not clear. The primary goal of this study was to compare the biomechanical response of synthetic 3D printed and polymeric materials against native aortic tissues. Toward this goal, tissue samples from the inner and outer curvature of ascending aorta were obtained from 20 healthy aortic donors. Bi-axial testing was performed on native aortic tissues, Stratasys TissueMatrix series, and silicone samples (Gluck Medical, Soul, Korea). Adult and pediatric aortic phantom with semilunar valves were 3D printed with TissueMatrix materials to perform functional testing. Our findings demonstrated that the elastic modulus of the 3D printed TissueMatrix materials was significantly higher than native aortic tissues at low tangent and high tangent modulus while no significant differences were found for silicone. Mean transvalvular pressure gradients in 3D printed aortic phantoms ranged from 3.5 mmHg to 6 mmHg for Reynolds number ranging from 2000 to 3500, respectively and increased to 25 mmHg at Reynolds number of 7000. 3D printed valves remained intact without fracture or tear even at high Reynolds number. Our work highlights that 3D printed materials are stiffer compared to native tissues with functional responses that resemble stiff native valves. Future work should focus on developing more compliant material mixtures that could ultimately support in device simulations and procedural planning.

Journal of Biomedical Materials Research Part AVol. 114(1)
University Health Network (CA), University of Toronto (CA), Ted Rogers Centre for Heart Research (CA), Toronto Metropolitan University (CA)
Natural Sciences and Engineering Research Council of Canada
Openalex Percentile: Top 94%
Soft Robotics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.