Accurate Cholesterol Level Detection Using an Electrochemical Wearable Biosensors

Background and Objectives: Cardiovascular diseases (CVDs) remain a leading cause of mortalityworldwide, with elevated serum cholesterol levels recognized as a primary risk factor. Conventional cholesterol monitoring methods are invasive and intermittent, highlighting the urgent need for noninvasive, real-time monitoring solutions. This study aimed to develop a nanoengineered wearable biosensor platform for accurate, continuous cholesterol monitoring, leveraging the catalytic properties of cerium oxide nanoparticles (CeO 2 NPs) integrated into platinum (Pt) electrodes. Cerium oxide nanoparticles were synthesized and stabilized using polyvinylpyrrolidone (PVP) and then immobilized onto Pt electrodes to fabricate a Pt/CeO 2 sensing platform. The catalytic oxidation of cholesterol was mediated via the peroxidase-mimetic activity of CeO 2 NPs, enabling the detection of hydrogen peroxide through the oxidation of 3,3′,5,5′-tetramethylbenzidine (TMB). Calibration curves were established across a cholesterol concentration range of 15–100 μM. Validation was performed using human sweat samples from 50 participants, comparing sensor outputs with standard enzymatic colorimetric assays. The biosensor demonstrated high analytical performance, with a limit of quantification (LOQ) of 5.7 μM and a detection sensitivity spanning 15–100 μM. Clinical validation revealed a correlation coefficient ( R ²) of 0.96 with standard assays, sensitivity of 94.2%, and specificity of 92.8%. The biosensor maintained operational stability under physiological variations, such as pH fluctuations and biofouling, due to engineered antifouling coatings and pH-compensated dual-electrode systems. The developed Pt/CeO 2 -based wearable biosensor enables noninvasive, accurate cholesterol monitoring in human sweat, offering a promising tool for personalized cardiovascular risk management. Future large-scale validation studies, including expanded demographic diversity and longitudinal assessment, are planned to further establish clinical applicability.

Authors

Institutions

Publication Details

Journal
Acupuncture & Electro-Therapeutics Research
Published
2025-07-20
DOI
https://doi.org/10.1177/03601293251356856
Primary Topic
Advanced Nanomaterials in Catalysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accurate Cholesterol Level Detection Using an Electrochemical Wearable Biosensors

Kalaiarasi Arumugam, Abiramee Ravi, KA Ibrahim Sheriff, Sre Adethya Viswam
Acupuncture & Electro-Therapeutics Research
Advanced Nanomaterials in Catalysis
article

Accurate Cholesterol Level Detection Using an Electrochemical Wearable Biosensors

Kalaiarasi Arumugam, Abiramee Ravi, KA Ibrahim Sheriff, Sre Adethya Viswam
article en

Abstract

Background and Objectives: Cardiovascular diseases (CVDs) remain a leading cause of mortalityworldwide, with elevated serum cholesterol levels recognized as a primary risk factor. Conventional cholesterol monitoring methods are invasive and intermittent, highlighting the urgent need for noninvasive, real-time monitoring solutions. This study aimed to develop a nanoengineered wearable biosensor platform for accurate, continuous cholesterol monitoring, leveraging the catalytic properties of cerium oxide nanoparticles (CeO 2 NPs) integrated into platinum (Pt) electrodes. Cerium oxide nanoparticles were synthesized and stabilized using polyvinylpyrrolidone (PVP) and then immobilized onto Pt electrodes to fabricate a Pt/CeO 2 sensing platform. The catalytic oxidation of cholesterol was mediated via the peroxidase-mimetic activity of CeO 2 NPs, enabling the detection of hydrogen peroxide through the oxidation of 3,3′,5,5′-tetramethylbenzidine (TMB). Calibration curves were established across a cholesterol concentration range of 15–100 μM. Validation was performed using human sweat samples from 50 participants, comparing sensor outputs with standard enzymatic colorimetric assays. The biosensor demonstrated high analytical performance, with a limit of quantification (LOQ) of 5.7 μM and a detection sensitivity spanning 15–100 μM. Clinical validation revealed a correlation coefficient ( R ²) of 0.96 with standard assays, sensitivity of 94.2%, and specificity of 92.8%. The biosensor maintained operational stability under physiological variations, such as pH fluctuations and biofouling, due to engineered antifouling coatings and pH-compensated dual-electrode systems. The developed Pt/CeO 2 -based wearable biosensor enables noninvasive, accurate cholesterol monitoring in human sweat, offering a promising tool for personalized cardiovascular risk management. Future large-scale validation studies, including expanded demographic diversity and longitudinal assessment, are planned to further establish clinical applicability.

Acupuncture & Electro-Therapeutics ResearchVol. 50(1)
Institute of Engineering (NP)
Good health and well-being
Openalex Percentile: Top 46%
Advanced Nanomaterials in Catalysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.