Experimental Analysis of the Post-Fire Structural Performance of Corroded Geopolymer Concrete Columns

This study investigates the combined effects of corrosion and fire on the structural performance of reinforced geopolymer concrete (GPC) columns. Four full-scale specimens were exposed to accelerated corrosion and ISO 834-standard fire conditions for 60–90 min. Key structural parameters—including axial load capacity, stiffness, ductility, toughness, and energy absorption—were evaluated to assess post-fire performance. Results show that both corrosion and fire independently reduce strength and stiffness, but their combined impact leads to severe degradation. The most heavily damaged specimens exhibited up to 79% loss in ultimate load, 64% loss in stiffness and over 90% reduction in energy absorption capacity. While some increases in ductility were observed under combined exposure, they were accompanied by substantial losses in load-bearing capacity. These severe reductions suggest that standard fire resistance assessments, when applied without considering prior corrosion, may significantly overestimate post-fire capacity, underscoring the need for corrosion deterioration models in structural fire design.

Authors

Institutions

Publication Details

Journal
Fire Technology
Published
2026-01-01
DOI
https://doi.org/10.1007/s10694-025-01844-5
Primary Topic
Fire effects on concrete materials
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental Analysis of the Post-Fire Structural Performance of Corroded Geopolymer Concrete Columns

Katherine A. Cashell, N. Anand, Alin Joe, Balamurali Kanagaraj et al.
Fire Technology
Fire effects on concrete materials
article

Experimental Analysis of the Post-Fire Structural Performance of Corroded Geopolymer Concrete Columns

Katherine A. Cashell, N. Anand, Alin Joe, Balamurali Kanagaraj, Kusum Lugun
article en

Abstract

This study investigates the combined effects of corrosion and fire on the structural performance of reinforced geopolymer concrete (GPC) columns. Four full-scale specimens were exposed to accelerated corrosion and ISO 834-standard fire conditions for 60–90 min. Key structural parameters—including axial load capacity, stiffness, ductility, toughness, and energy absorption—were evaluated to assess post-fire performance. Results show that both corrosion and fire independently reduce strength and stiffness, but their combined impact leads to severe degradation. The most heavily damaged specimens exhibited up to 79% loss in ultimate load, 64% loss in stiffness and over 90% reduction in energy absorption capacity. While some increases in ductility were observed under combined exposure, they were accompanied by substantial losses in load-bearing capacity. These severe reductions suggest that standard fire resistance assessments, when applied without considering prior corrosion, may significantly overestimate post-fire capacity, underscoring the need for corrosion deterioration models in structural fire design.

Fire TechnologyVol. 62(1)
Karunya University (IN), University College London (GB)
Karunya University
Affordable and clean energy
Openalex Percentile: Top 94%
Fire effects on concrete materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Experimental Analysis of the Post-Fire Structural Performance of Corroded Geopolymer Concrete Columns — Katherine A. Cashell, N. Anand, et al. · Fire Technology (2026) | TGRS Research Map | TGRS