Preliminary evaluation of a passive upper-limb exoskeleton based on a new spring design

Upper limb exoskeletons may be valuable tools to decrease the risk to develop musculoskeletal disorders, and their design may differ from one manufacturer to another. The aim of the present study is to evaluate a passive upper limb exoskeleton based on a new spring design comprised of composite spring rods. Twelve right-handed participants have performed three manual tasks: static overhead holding, manual handling, and load carrying, with and without the upper limb exoskeleton. EMG activity of the anterior deltoid and biceps brachii was significantly reduced across the three tasks when wearing the exoskeleton. These findings suggested that the upper limb exoskeleton based on this new spring device permitted to reduce shoulder-flexor muscular demand through the tested experimental tasks. Longer-duration, in-field studies are now required to assess the efficacy of this exoskeleton for workers and potential implications for MSD prevention.

Authors

Institutions

Publication Details

Journal
Ergonomics
Published
2026-01-06
DOI
https://doi.org/10.1080/00140139.2025.2608277
Primary Topic
Prosthetics and Rehabilitation Robotics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Preliminary evaluation of a passive upper-limb exoskeleton based on a new spring design

Nicolas Vignais, Thomas Albouy, Béatrice Le Tellier, K. Lebel
Ergonomics
Prosthetics and Rehabilitation Robotics
article

Preliminary evaluation of a passive upper-limb exoskeleton based on a new spring design

Nicolas Vignais, Thomas Albouy, Béatrice Le Tellier, K. Lebel
article en

Abstract

Upper limb exoskeletons may be valuable tools to decrease the risk to develop musculoskeletal disorders, and their design may differ from one manufacturer to another. The aim of the present study is to evaluate a passive upper limb exoskeleton based on a new spring design comprised of composite spring rods. Twelve right-handed participants have performed three manual tasks: static overhead holding, manual handling, and load carrying, with and without the upper limb exoskeleton. EMG activity of the anterior deltoid and biceps brachii was significantly reduced across the three tasks when wearing the exoskeleton. These findings suggested that the upper limb exoskeleton based on this new spring device permitted to reduce shoulder-flexor muscular demand through the tested experimental tasks. Longer-duration, in-field studies are now required to assess the efficacy of this exoskeleton for workers and potential implications for MSD prevention.

Ergonomics
Université Paris-Sud (FR), Université Paris-Saclay (FR), Université Rennes 2 (FR), Centre Inria de l'Université de Rennes (FR), Université de Rennes (FR)
Openalex Percentile: Top 94%
Prosthetics and Rehabilitation Robotics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Preliminary evaluation of a passive upper-limb exoskeleton based on a new spring design — Nicolas Vignais, Thomas Albouy, et al. · Ergonomics (2026) | TGRS Research Map | TGRS