A Simple and Cost-Effective Retractor for Transorbital Neurosurgery: Technical Note and Application in Lacrimal Keyhole Approaches

<b>Background</b>: Transorbital approaches (TOAs) provide minimally invasive access to anterior and middle cranial fossa lesions. However, orbital retraction remains a challenge, as narrow corridors limit maneuverability and excessive retraction increase complication risk. Conventional rigid or malleable retractors may obstruct the corridor or exert uneven pressure on delicate tissues. We present a handmade, semi-rigid plastic retractor as a low-cost, effective solution to optimize orbital retraction in TOAs. <b>Methods</b>: The retractor was fashioned from a cylindrical plastic drill bit container, cut into two semicircular pieces with rounded edges. Its application is described within the transorbital eyebrow lacrimal keyhole approach (TELKA). During the bony phase, one piece is placed on the orbital roof for periorbital retraction and protection, while a second may be positioned laterally to protect the temporalis muscle when required. Once adequate working space is achieved, the lateral retractor is removed and the medial one maintained throughout the procedure. Technical details are illustrated through representative clinical cases, supported by anatomical dissection and an operative video. <b>Results</b>: Across thirteen TELKA procedures, the semi-rigid retractor provided stable, low-intensity retraction with even pressure distribution, minimizing corridor obstruction and facilitating both microscopic and endoscopic maneuverability. No orbital or visual complications related to retraction were observed; periorbital structures were preserved, with no postoperative proptosis or aesthetic defects. <b>Conclusions</b>: This handmade, semi-rigid retractor is a safe, customizable, and reproducible tool that enhances surgical freedom while minimizing orbital morbidity in TOAs. It is particularly advantageous in keyhole procedures such as TELKA, representing a promising alternative to conventional retraction systems.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2026-01-07
DOI
https://doi.org/10.3390/jcm15020482
Primary Topic
Facial Trauma and Fracture Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Simple and Cost-Effective Retractor for Transorbital Neurosurgery: Technical Note and Application in Lacrimal Keyhole Approaches

Luca Ferlendis, Rosaria Abbritti, Thibault Passeri, Sébastien Froelich et al.
Journal of Clinical Medicine
Facial Trauma and Fracture Management
article

A Simple and Cost-Effective Retractor for Transorbital Neurosurgery: Technical Note and Application in Lacrimal Keyhole Approaches

Luca Ferlendis, Rosaria Abbritti, Thibault Passeri, Sébastien Froelich, Arianna Fava
article en

Abstract

<b>Background</b>: Transorbital approaches (TOAs) provide minimally invasive access to anterior and middle cranial fossa lesions. However, orbital retraction remains a challenge, as narrow corridors limit maneuverability and excessive retraction increase complication risk. Conventional rigid or malleable retractors may obstruct the corridor or exert uneven pressure on delicate tissues. We present a handmade, semi-rigid plastic retractor as a low-cost, effective solution to optimize orbital retraction in TOAs. <b>Methods</b>: The retractor was fashioned from a cylindrical plastic drill bit container, cut into two semicircular pieces with rounded edges. Its application is described within the transorbital eyebrow lacrimal keyhole approach (TELKA). During the bony phase, one piece is placed on the orbital roof for periorbital retraction and protection, while a second may be positioned laterally to protect the temporalis muscle when required. Once adequate working space is achieved, the lateral retractor is removed and the medial one maintained throughout the procedure. Technical details are illustrated through representative clinical cases, supported by anatomical dissection and an operative video. <b>Results</b>: Across thirteen TELKA procedures, the semi-rigid retractor provided stable, low-intensity retraction with even pressure distribution, minimizing corridor obstruction and facilitating both microscopic and endoscopic maneuverability. No orbital or visual complications related to retraction were observed; periorbital structures were preserved, with no postoperative proptosis or aesthetic defects. <b>Conclusions</b>: This handmade, semi-rigid retractor is a safe, customizable, and reproducible tool that enhances surgical freedom while minimizing orbital morbidity in TOAs. It is particularly advantageous in keyhole procedures such as TELKA, representing a promising alternative to conventional retraction systems.

Journal of Clinical MedicineVol. 15(2)
Hôpital Lariboisière (FR)
Peace, Justice and strong institutions
Openalex Percentile: Top 94%
Facial Trauma and Fracture Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.