Thumb–Index Guide Manoeuvre to Potentially Keep Needle In-plane during Interventional Ultrasound

It has been observed that ultrasonographic needle insertion, whether in-plane or out-of-plane, could be facilitated by needle guidance devices/manoeuvres.[1-3] However, needle guidance devices may sometimes be inaccessible,[4] while proceduralists may sometimes be inexperienced in needle guidance manoeuvres. Therefore, to ergonomically guide the needle in-plane, herein described simple technique may prove useful to maintain a continuous visualisation of the in-plane needle. As simulated in Figure 1 with a hockey stick-shaped linear array probe [Figure 1a] and standard-shaped linear array probe [Figure 1b], the proceduralist’s thumb–index finger [as indicated by red arrows in Figure 1] can guide and keep the needle in-plane so that the needle moving in-plane remains continuously visible. As Figure 1a and b comparatively depicts the two probes, it seems apparent that the hockey stick-shaped linear array probe with its smaller footprint in the proceduralist’s hand can be advantageous for this thumb–index guide manoeuvre as compared to standard-shaped linear array probe with its larger footprint in the proceduralist’s hand. While exercising additional caution with regard to needle-stick injury, it may concurrently be ideal to use sterile gloves for this thumb–index guide manoeuvre in case the moving needle inadvertently contacts the gloved thumb–index finger. Moreover, during in-plane ultrasound imaging for vascular access,[5-7] it may be better to choose a site of insertion where the vein and the artery have sufficient lateral separation to reduce the risk for inadvertent arterial puncture during the intended venipuncture. In a nutshell, simple adjustment by proceduralist in holding the ultrasound probe with the thumb–index finger projecting further beyond the ultrasound probe may guide and manoeuvre the needle insertion during the in-plane ultrasonography for interventional procedures.Figure 1: (a and b) Simulated thumb–index guide manoeuvre with red arrows highlighting thumb–index finger holding hockey stick-shaped linear array probe, (a) and standard-shaped linear array probe (b)Authors’ contributions DG: Contributed to concept, simulation, manuscript preparation, manuscript editing and manuscript review, DB: Contributed to simulation, manuscript editing and manuscript review. Financial support and sponsorship Nil. Conflicts of interest There are no conflicts of interest.

Authors

Institutions

Publication Details

Journal
NMO journal
Published
2026-01-01
DOI
https://doi.org/10.4103/jnmo.jnmo_100_25
Primary Topic
Central Venous Catheters and Hemodialysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thumb–Index Guide Manoeuvre to Potentially Keep Needle In-plane during Interventional Ultrasound

Deepak Gupta, Dilip Baral
NMO journal
Central Venous Catheters and Hemodialysis
article

Thumb–Index Guide Manoeuvre to Potentially Keep Needle In-plane during Interventional Ultrasound

Deepak Gupta, Dilip Baral
article en

Abstract

It has been observed that ultrasonographic needle insertion, whether in-plane or out-of-plane, could be facilitated by needle guidance devices/manoeuvres.[1-3] However, needle guidance devices may sometimes be inaccessible,[4] while proceduralists may sometimes be inexperienced in needle guidance manoeuvres. Therefore, to ergonomically guide the needle in-plane, herein described simple technique may prove useful to maintain a continuous visualisation of the in-plane needle. As simulated in Figure 1 with a hockey stick-shaped linear array probe [Figure 1a] and standard-shaped linear array probe [Figure 1b], the proceduralist’s thumb–index finger [as indicated by red arrows in Figure 1] can guide and keep the needle in-plane so that the needle moving in-plane remains continuously visible. As Figure 1a and b comparatively depicts the two probes, it seems apparent that the hockey stick-shaped linear array probe with its smaller footprint in the proceduralist’s hand can be advantageous for this thumb–index guide manoeuvre as compared to standard-shaped linear array probe with its larger footprint in the proceduralist’s hand. While exercising additional caution with regard to needle-stick injury, it may concurrently be ideal to use sterile gloves for this thumb–index guide manoeuvre in case the moving needle inadvertently contacts the gloved thumb–index finger. Moreover, during in-plane ultrasound imaging for vascular access,[5-7] it may be better to choose a site of insertion where the vein and the artery have sufficient lateral separation to reduce the risk for inadvertent arterial puncture during the intended venipuncture. In a nutshell, simple adjustment by proceduralist in holding the ultrasound probe with the thumb–index finger projecting further beyond the ultrasound probe may guide and manoeuvre the needle insertion during the in-plane ultrasonography for interventional procedures.Figure 1: (a and b) Simulated thumb–index guide manoeuvre with red arrows highlighting thumb–index finger holding hockey stick-shaped linear array probe, (a) and standard-shaped linear array probe (b)Authors’ contributions DG: Contributed to concept, simulation, manuscript preparation, manuscript editing and manuscript review, DB: Contributed to simulation, manuscript editing and manuscript review. Financial support and sponsorship Nil. Conflicts of interest There are no conflicts of interest.

NMO journalVol. 20(1)
Wayne State University (US), Detroit Medical Center (US)
Openalex Percentile: Top 96%
Central Venous Catheters and Hemodialysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.