Determining the Detectability of H <sub>2</sub> O with Photometric Observations Using Bayesian Analysis for Remote Biosignature Identification on exo-Earths (BARBIE)

Abstract We examine the detectability of water (H 2 O) in the reflected-light spectrum of an Earth-like exoplanet assuming a photometric observational approach rather than spectroscopic. By quantifying the detectability as a function of normalized exposure time, resolving power ( R ), and amount of spectral points, we can constrain whether spectroscopy or photometry is the more efficient observing procedure to detect H 2 O at varying abundances by measuring the broad 0.94 μ m absorption feature using the Habitable Worlds Observatory (HWO). We simulate low-resolution spectroscopy ( R = 10, 20, and 30, presented as a photometric bandwidth fraction of 10%, 5%, and 3% herein) as a proxy for narrowband photometric observations, and constrain the wavelength range from 0.85 to 1.05 μ m to narrow focus on the 0.9 μ m feature. We then constrain the number of spectral points to two or three points at each bandwidth fraction to investigate the impact of spectral point placement on detectability. Additionally, we take the signal-to-noise ratios for strong H 2 O detection and calculate the resultant exoplanet yields assuming photometric observation and compare to the yields from higher-resolution spectroscopic observations under different noise instances, characterization wavelengths, noise floors, and aperture sizes. We find that H 2 O is strongly detectable at all bandwidth fractions depending on the spectral point placement, requiring a minimum of three spectral points, at a variety of normalized exposure times depending on the abundance of H 2 O. We also find that the detector noise is the main driver in determining whether photometry or spectroscopy results in higher yields. Photometry is the preferred observational method in high-noise cases, while spectroscopy is preferred in low-noise scenarios.

Authors

Publication Details

Journal
The Astronomical Journal
Published
2026-01-08
DOI
https://doi.org/10.3847/1538-3881/ae29b1
Primary Topic
Astro and Planetary Science
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determining the Detectability of H 2 O with Photometric Observations Using Bayesian Analysis for Remote Biosignature Identification on exo-Earths (BARBIE)

Avi Mandell, Natasha Latouf, Vincent Kofman, Chris Stark
The Astronomical Journal
Astro and Planetary Science
article

Determining the Detectability of H 2 O with Photometric Observations Using Bayesian Analysis for Remote Biosignature Identification on exo-Earths (BARBIE)

Avi Mandell, Natasha Latouf, Vincent Kofman, Chris Stark
article en

Abstract

Abstract We examine the detectability of water (H 2 O) in the reflected-light spectrum of an Earth-like exoplanet assuming a photometric observational approach rather than spectroscopic. By quantifying the detectability as a function of normalized exposure time, resolving power ( R ), and amount of spectral points, we can constrain whether spectroscopy or photometry is the more efficient observing procedure to detect H 2 O at varying abundances by measuring the broad 0.94 μ m absorption feature using the Habitable Worlds Observatory (HWO). We simulate low-resolution spectroscopy ( R = 10, 20, and 30, presented as a photometric bandwidth fraction of 10%, 5%, and 3% herein) as a proxy for narrowband photometric observations, and constrain the wavelength range from 0.85 to 1.05 μ m to narrow focus on the 0.9 μ m feature. We then constrain the number of spectral points to two or three points at each bandwidth fraction to investigate the impact of spectral point placement on detectability. Additionally, we take the signal-to-noise ratios for strong H 2 O detection and calculate the resultant exoplanet yields assuming photometric observation and compare to the yields from higher-resolution spectroscopic observations under different noise instances, characterization wavelengths, noise floors, and aperture sizes. We find that H 2 O is strongly detectable at all bandwidth fractions depending on the spectral point placement, requiring a minimum of three spectral points, at a variety of normalized exposure times depending on the abundance of H 2 O. We also find that the detector noise is the main driver in determining whether photometry or spectroscopy results in higher yields. Photometry is the preferred observational method in high-noise cases, while spectroscopy is preferred in low-noise scenarios.

The Astronomical JournalVol. 171(2)
Openalex Percentile: Top 92%
Astro and Planetary Science
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Determining the Detectability of H <sub>2</sub> O with Photometric Observations Using Bayesian Analysis for Remote Biosignature Identification on exo-Earths (BARBIE) — Avi Mandell, Natasha Latouf, et al. · The Astronomical Journal (2026) | TGRS Research Map | TGRS