Molecularly Imprinted Polymer-Based Electrogenerated Chemiluminescence Sensor for Sensitive and Selective Fentanyl Detection

The escalating prevalence of fentanyl, a highly potent synthetic opioid responsible for rising overdose fatalities and public health crises, underscores the critical need for sensitive and selective detection methodologies. Herein, we report a molecularly imprinted polymer (MIP)-based electrogenerated chemiluminescence (ECL) sensor for ultrasensitive and selective quantification of fentanyl. The sensor was fabricated by electropolymerizing 4-aminobenzoic acid (4-ABA) on a glassy carbon electrode (GCE) in the presence of fentanyl as the template, followed by template elution to yield recognition nanocavities within the MIP film. ECL signal transduction was achieved through the anodic coreactant pathway, wherein fentanyl (as the coreactant) bound within the MIP cavities reacted with solution-phase [Ru(bpy)<sub>3</sub>]<sup>2+</sup> (as the ECL emitter) in phosphate buffer (pH 7.5) during anodic scans from 0 to 1.60 V vs Ag/AgCl (3.0 M KCl). Critical fabrication and operational parameters, including electropolymerization cycles, template concentration and molar ratio to the monomer, elution conditions, and rebinding duration, were systematically optimized. Density functional theory and density of states investigations guided elution solvent selection and elucidated favorable fentanyl-polymer interactions, verifying the sensor's specificity toward fentanyl over five common structurally similar interferents. Under optimized conditions, the MIP-ECL sensor exhibited a limit of detection of ∼1 μM (S/N = 3), equivalent to 3.4 ng of fentanyl using 10 μL solution, with three distinctive linear regions spanning 1.0 to 6.0, 6.0 to 40.0, and 40.0 to 70.0 μM. Additionally, the sensor demonstrated high reproducibility and stability, positioning it as a promising platform for rapid forensic analysis of illicit fentanyl.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2026-01-07
DOI
https://doi.org/10.1021/acs.analchem.5c06407
Primary Topic
Forensic Toxicology and Drug Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Molecularly Imprinted Polymer-Based Electrogenerated Chemiluminescence Sensor for Sensitive and Selective Fentanyl Detection

Arati Biswakarma, Wujian Miao
Analytical Chemistry
Forensic Toxicology and Drug Analysis
article

Molecularly Imprinted Polymer-Based Electrogenerated Chemiluminescence Sensor for Sensitive and Selective Fentanyl Detection

Arati Biswakarma, Wujian Miao
article en

Abstract

The escalating prevalence of fentanyl, a highly potent synthetic opioid responsible for rising overdose fatalities and public health crises, underscores the critical need for sensitive and selective detection methodologies. Herein, we report a molecularly imprinted polymer (MIP)-based electrogenerated chemiluminescence (ECL) sensor for ultrasensitive and selective quantification of fentanyl. The sensor was fabricated by electropolymerizing 4-aminobenzoic acid (4-ABA) on a glassy carbon electrode (GCE) in the presence of fentanyl as the template, followed by template elution to yield recognition nanocavities within the MIP film. ECL signal transduction was achieved through the anodic coreactant pathway, wherein fentanyl (as the coreactant) bound within the MIP cavities reacted with solution-phase [Ru(bpy)<sub>3</sub>]<sup>2+</sup> (as the ECL emitter) in phosphate buffer (pH 7.5) during anodic scans from 0 to 1.60 V vs Ag/AgCl (3.0 M KCl). Critical fabrication and operational parameters, including electropolymerization cycles, template concentration and molar ratio to the monomer, elution conditions, and rebinding duration, were systematically optimized. Density functional theory and density of states investigations guided elution solvent selection and elucidated favorable fentanyl-polymer interactions, verifying the sensor's specificity toward fentanyl over five common structurally similar interferents. Under optimized conditions, the MIP-ECL sensor exhibited a limit of detection of ∼1 μM (S/N = 3), equivalent to 3.4 ng of fentanyl using 10 μL solution, with three distinctive linear regions spanning 1.0 to 6.0, 6.0 to 40.0, and 40.0 to 70.0 μM. Additionally, the sensor demonstrated high reproducibility and stability, positioning it as a promising platform for rapid forensic analysis of illicit fentanyl.

Analytical ChemistryVol. 98(2)
University of Southern Mississippi (US)
Good health and well-being
Openalex Percentile: Top 95%
Forensic Toxicology and Drug Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Molecularly Imprinted Polymer-Based Electrogenerated Chemiluminescence Sensor for Sensitive and Selective Fentanyl Detection — Arati Biswakarma, Wujian Miao · Analytical Chemistry (2026) | TGRS Research Map | TGRS