Machine Learning-Enabled Image Comparability Assessment for Flow Imaging Microscopy Across Platforms

<b>Background/Objectives</b>: The rapid development of biopharmaceuticals has heightened attention from both industry and regulatory agencies toward product quality, particularly regarding subvisible particles as a critical quality attribute. Existing pharmacopoeial methods, Light Obscuration (LO) and Microscopic Particle Count (MC), exhibit limitations in meeting increasingly refined analytical requirements. Flow Imaging Microscopy (FIM) technology shows promise as an alternative, yet its standardized methodologies are still under development. <b>Methods</b>: This study employed polystyrene microsphere standard beads and intravenous immunoglobulin to perform instrument standardization and consistency evaluations on FIM instruments sharing the same operating principles but from different manufacturers. The consistency and transferability of particle counting across platforms were assessed. Additionally, particle images obtained from parallel testing on two platforms were classified using confusion matrices based on convolutional neural networks and the Unified Manifold Approximation and Projection (UMAP) dimensionality reduction method. <b>Results</b>: This study investigated the consistency and developed a transfer strategy for particle counting results across different FIM platforms. Analysis of particle image classification confirmed the consistency of image-based categorization while also revealing the complexity associated with cross-platform image recognition. <b>Conclusions</b>: The findings provide valuable insights for the further standardization of Flow Imaging Microscopy, supporting its potential as a reliable analytical tool for subvisible particle analysis in biopharmaceutical quality control.

Authors

Institutions

Publication Details

Journal
Pharmaceuticals
Published
2026-01-07
DOI
https://doi.org/10.3390/ph19010107
Primary Topic
Protein purification and stability
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Machine Learning-Enabled Image Comparability Assessment for Flow Imaging Microscopy Across Platforms

H Li, Y. T. Tian, Hao Wu, D. Li et al.
Pharmaceuticals
Protein purification and stability
article

Machine Learning-Enabled Image Comparability Assessment for Flow Imaging Microscopy Across Platforms

H Li, Y. T. Tian, Hao Wu, D. Li, Zhenhao Zhou, Zhiyun Qi, Xiaoying Chen, Sha Guo, Jiaxin Li, Pengfei He
article en

Abstract

<b>Background/Objectives</b>: The rapid development of biopharmaceuticals has heightened attention from both industry and regulatory agencies toward product quality, particularly regarding subvisible particles as a critical quality attribute. Existing pharmacopoeial methods, Light Obscuration (LO) and Microscopic Particle Count (MC), exhibit limitations in meeting increasingly refined analytical requirements. Flow Imaging Microscopy (FIM) technology shows promise as an alternative, yet its standardized methodologies are still under development. <b>Methods</b>: This study employed polystyrene microsphere standard beads and intravenous immunoglobulin to perform instrument standardization and consistency evaluations on FIM instruments sharing the same operating principles but from different manufacturers. The consistency and transferability of particle counting across platforms were assessed. Additionally, particle images obtained from parallel testing on two platforms were classified using confusion matrices based on convolutional neural networks and the Unified Manifold Approximation and Projection (UMAP) dimensionality reduction method. <b>Results</b>: This study investigated the consistency and developed a transfer strategy for particle counting results across different FIM platforms. Analysis of particle image classification confirmed the consistency of image-based categorization while also revealing the complexity associated with cross-platform image recognition. <b>Conclusions</b>: The findings provide valuable insights for the further standardization of Flow Imaging Microscopy, supporting its potential as a reliable analytical tool for subvisible particle analysis in biopharmaceutical quality control.

PharmaceuticalsVol. 19(1)
Shenyang Pharmaceutical University (CN), Shanghai Jiao Tong University (CN), National Medical Products Administration (CN), National Institutes for Food and Drug Control (CN)
Industry, innovation and infrastructure
Openalex Percentile: Top 95%
Protein purification and stability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.