Can one use serum Lactate Concentration to Correct for the Anion gap?

Patients in the intensive care unit often develop anion gap metabolic acidosis most commonly from lactic acidosis. Clinicians routinely measure serum lactate levels, but it is not clear if one is able to use the measured serum lactate level to determine if there is a second cause for anion gap metabolic acidosis in these critically ill patients. In this report, 503 episodes of lactic acidosis with serum lactate levels greater than 5 mmol/L at a single institution over two years were analyzed. The average serum anion gap minus serum lactate level in these patients was 6.9 ± 0.21 mEq/L, the average corrected anion gap was -1.3 ± 0.23 mEq/L and the average strong ion gap was 5.1 ± 0.3 mEq/L. The majority of the episodes with anion gap-serum lactate concentration >8.0 mEq/L were explained by elevated serum albumin concentration, elevated serum phosphorus concentration, presence of ketones in the urine or high β-hydroxybutyrate concentrations. The above data suggest that one can use the measured serum lactate concentration and subtract from the serum anion gap to determine if there is a second reason for anion gap metabolic acidosis.

Authors

Institutions

Publication Details

Journal
Journal of Intensive Care Medicine
Published
2026-01-06
DOI
https://doi.org/10.1177/08850666251411921
Primary Topic
Renal function and acid-base balance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Can one use serum Lactate Concentration to Correct for the Anion gap?

Na Zhou, Jonathan G. Amatruda, Ramin Sam, Emilio Fernandez et al.
Journal of Intensive Care Medicine
Renal function and acid-base balance
article

Can one use serum Lactate Concentration to Correct for the Anion gap?

Na Zhou, Jonathan G. Amatruda, Ramin Sam, Emilio Fernandez, Antonios H. Tzamaloukas
article en

Abstract

Patients in the intensive care unit often develop anion gap metabolic acidosis most commonly from lactic acidosis. Clinicians routinely measure serum lactate levels, but it is not clear if one is able to use the measured serum lactate level to determine if there is a second cause for anion gap metabolic acidosis in these critically ill patients. In this report, 503 episodes of lactic acidosis with serum lactate levels greater than 5 mmol/L at a single institution over two years were analyzed. The average serum anion gap minus serum lactate level in these patients was 6.9 ± 0.21 mEq/L, the average corrected anion gap was -1.3 ± 0.23 mEq/L and the average strong ion gap was 5.1 ± 0.3 mEq/L. The majority of the episodes with anion gap-serum lactate concentration >8.0 mEq/L were explained by elevated serum albumin concentration, elevated serum phosphorus concentration, presence of ketones in the urine or high β-hydroxybutyrate concentrations. The above data suggest that one can use the measured serum lactate concentration and subtract from the serum anion gap to determine if there is a second reason for anion gap metabolic acidosis.

Journal of Intensive Care Medicine
San Francisco General Hospital (US)
Openalex Percentile: Top 95%
Renal function and acid-base balance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.