Imaging of Small Lung Nodules on Modern SAFOV and LAFOV PET in Combination With Data-driven Motion Correction: Implications for Current Practice.

Purpose Guidelines recommend [18F]FDG PET/CT for lung nodules >8 mm only. For smaller lesions, PET/CT has not been recommended due to lower lesion conspicuity. However, this threshold was established using earlier generations of PET scanners. In this work, we sought to evaluate the combined effects of modern scanner technology, long-axial-field-of-view (LAFOV) PET and data-driven respiratory motion correction on lung nodule imaging.Materials And Methods We identified 55 consecutive patients with lung nodules who underwent [18F]FDG PET/CT for a known or suspected malignancy. We created image reconstructions with combinations of simulated short-axial-field-of-view (sSAFOV), LAFOV, and data-driven gating (DDG) and measured effects on image parameters. We then gathered follow-up data (over 13 mo) to establish nodule benignity or malignancy and evaluated effects on diagnostic accuracy with receiver-operating-characteristic (ROC) analysis.Results All methods showed good to excellent diagnostic accuracy, even for nodules <6 mm, with AUCs consistently above 0.85. LAFOV reduced noise compared with sSAFOV, and adding DDG increased the median SUVmax by 32%. The combination of LAFOV and DDG showed the highest image quality improvement compared with sSAFOV, with a median improvement in contrast-to-noise ratio (CNR) of 29%.Conclusions Data-driven motion correction and LAFOV-PET provide synergistic improvements in image quality. Furthermore, the high diagnostic accuracy of sSAFOV reconstructions for lung nodules ≤8 mm, and even <6 mm, indicates that assessment of lung nodules smaller than current guideline recommendations might be possible.

Authors

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2026-01-07
DOI
https://doi.org/10.48620/93647
Primary Topic
Lung Cancer Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Imaging of Small Lung Nodules on Modern SAFOV and LAFOV PET in Combination With Data-driven Motion Correction: Implications for Current Practice.

Clemens Mingels, R. Seifert, Federico Caobelli, Axel Rominger et al.
Open Access CRIS of the University of Bern
Lung Cancer Diagnosis and Treatment
article

Imaging of Small Lung Nodules on Modern SAFOV and LAFOV PET in Combination With Data-driven Motion Correction: Implications for Current Practice.

Clemens Mingels, R. Seifert, Federico Caobelli, Axel Rominger, Carola Bregenzer, Marco Viscione, Alexander Weissensee, Hasan Sari, Thomas Pyka
article en

Abstract

Purpose Guidelines recommend [18F]FDG PET/CT for lung nodules >8 mm only. For smaller lesions, PET/CT has not been recommended due to lower lesion conspicuity. However, this threshold was established using earlier generations of PET scanners. In this work, we sought to evaluate the combined effects of modern scanner technology, long-axial-field-of-view (LAFOV) PET and data-driven respiratory motion correction on lung nodule imaging.Materials And Methods We identified 55 consecutive patients with lung nodules who underwent [18F]FDG PET/CT for a known or suspected malignancy. We created image reconstructions with combinations of simulated short-axial-field-of-view (sSAFOV), LAFOV, and data-driven gating (DDG) and measured effects on image parameters. We then gathered follow-up data (over 13 mo) to establish nodule benignity or malignancy and evaluated effects on diagnostic accuracy with receiver-operating-characteristic (ROC) analysis.Results All methods showed good to excellent diagnostic accuracy, even for nodules <6 mm, with AUCs consistently above 0.85. LAFOV reduced noise compared with sSAFOV, and adding DDG increased the median SUVmax by 32%. The combination of LAFOV and DDG showed the highest image quality improvement compared with sSAFOV, with a median improvement in contrast-to-noise ratio (CNR) of 29%.Conclusions Data-driven motion correction and LAFOV-PET provide synergistic improvements in image quality. Furthermore, the high diagnostic accuracy of sSAFOV reconstructions for lung nodules ≤8 mm, and even <6 mm, indicates that assessment of lung nodules smaller than current guideline recommendations might be possible.

Open Access CRIS of the University of Bern
Good health and well-being
Openalex Percentile: Top 95%
Lung Cancer Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.