Slot fidelity and ligation-dependent tribology in personalized brackets made by casting versus selective laser melting: an in vitro study
Reliable chairside adoption of digital orthodontics depends on micrometre-scale slot fidelity and stable bracket-wire tribology. A single computer-aided design for a personalized second-premolar bracket was manufactured by lost-wax casting and by selective laser melting (SLM) (n = 36 per method). Slot height and inter-wall angle were measured on both the support-facing and non-support surfaces. Static and dynamic friction were evaluated using stainless-steel rectangular wires ligated either with tightly twisted stainless-steel ties or with elastomeric modules. Mean slot height was 480.88 ± 73.90 µm for casting and 421.47 ± 32.03 µm for SLM, against a nominal 480 µm. Overall height error did not differ between methods (P = 0.673), whereas angle er-ror was greater for SLM (17.76 ± 11.29°) than for casting (9.56 ± 8.88°, P < 0.001). The support-facing wall consistently showed reduced accuracy: in casting, height error in-creased on the support side (P = 0.001); in SLM, both height and angle errors increased on the support side (both P < 0.001). Across conditions, static friction exceeded dynamic friction (all P < 0.001). With steel ligation, friction was higher for casting than SLM (median static 6.00 N vs 4.35 N, P = 0.007; median dynamic 5.03 N vs 3.83 N, P = 0.011). With elastomeric ligation, the ranking reversed, with higher friction for SLM (median static 2.95 N vs 2.05 N, P < 0.001; median dynamic 2.54 N vs 2.03 N, P = 0.003). In this standardized local in vitro model, findings suggest a surface-dependent reduction in accuracy at the support-facing wall and a fabrication-by-ligation interaction that may alter the frictional ranking between steel and elastomeric ligations. Cast brackets showed more consistent full-wire seating, whereas SLM brackets may benefit from calibrated design offsets and targeted finishing to limit undersized or tapered slots; validation beyond this setup is needed.
Authors
- Thi Bich Ngoc Ha
- Viet Anh Nguyen (ORCID: https://orcid.org/0000-0002-0087-6403)
- N. H. Pham
- Viet Hoang
- Minh Tâm Tran (ORCID: https://orcid.org/0009-0003-3677-9888)
- Thi Quynh Trang Vuong
Institutions
- Van Lang University (VN)
- Phenikaa University (VN)
Publication Details
- Journal
- Scientific Reports
- Published
- 2026-01-06
- DOI
- https://doi.org/10.1038/s41598-025-34810-w
- Primary Topic
- Orthodontics and Dentofacial Orthopedics
- Type
- article
- Field-Weighted Citation Impact
- 0.00