Slot fidelity and ligation-dependent tribology in personalized brackets made by casting versus selective laser melting: an in vitro study

Reliable chairside adoption of digital orthodontics depends on micrometre-scale slot fidelity and stable bracket-wire tribology. A single computer-aided design for a personalized second-premolar bracket was manufactured by lost-wax casting and by selective laser melting (SLM) (n = 36 per method). Slot height and inter-wall angle were measured on both the support-facing and non-support surfaces. Static and dynamic friction were evaluated using stainless-steel rectangular wires ligated either with tightly twisted stainless-steel ties or with elastomeric modules. Mean slot height was 480.88 ± 73.90 µm for casting and 421.47 ± 32.03 µm for SLM, against a nominal 480 µm. Overall height error did not differ between methods (P = 0.673), whereas angle er-ror was greater for SLM (17.76 ± 11.29°) than for casting (9.56 ± 8.88°, P < 0.001). The support-facing wall consistently showed reduced accuracy: in casting, height error in-creased on the support side (P = 0.001); in SLM, both height and angle errors increased on the support side (both P < 0.001). Across conditions, static friction exceeded dynamic friction (all P < 0.001). With steel ligation, friction was higher for casting than SLM (median static 6.00 N vs 4.35 N, P = 0.007; median dynamic 5.03 N vs 3.83 N, P = 0.011). With elastomeric ligation, the ranking reversed, with higher friction for SLM (median static 2.95 N vs 2.05 N, P < 0.001; median dynamic 2.54 N vs 2.03 N, P = 0.003). In this standardized local in vitro model, findings suggest a surface-dependent reduction in accuracy at the support-facing wall and a fabrication-by-ligation interaction that may alter the frictional ranking between steel and elastomeric ligations. Cast brackets showed more consistent full-wire seating, whereas SLM brackets may benefit from calibrated design offsets and targeted finishing to limit undersized or tapered slots; validation beyond this setup is needed.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-01-06
DOI
https://doi.org/10.1038/s41598-025-34810-w
Primary Topic
Orthodontics and Dentofacial Orthopedics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Slot fidelity and ligation-dependent tribology in personalized brackets made by casting versus selective laser melting: an in vitro study

Thi Bich Ngoc Ha, Viet Anh Nguyen, N. H. Pham, Viet Hoang et al.
Scientific Reports
Orthodontics and Dentofacial Orthopedics
article

Slot fidelity and ligation-dependent tribology in personalized brackets made by casting versus selective laser melting: an in vitro study

Thi Bich Ngoc Ha, Viet Anh Nguyen, N. H. Pham, Viet Hoang, Minh Tâm Tran, Thi Quynh Trang Vuong
article en

Abstract

Reliable chairside adoption of digital orthodontics depends on micrometre-scale slot fidelity and stable bracket-wire tribology. A single computer-aided design for a personalized second-premolar bracket was manufactured by lost-wax casting and by selective laser melting (SLM) (n = 36 per method). Slot height and inter-wall angle were measured on both the support-facing and non-support surfaces. Static and dynamic friction were evaluated using stainless-steel rectangular wires ligated either with tightly twisted stainless-steel ties or with elastomeric modules. Mean slot height was 480.88 ± 73.90 µm for casting and 421.47 ± 32.03 µm for SLM, against a nominal 480 µm. Overall height error did not differ between methods (P = 0.673), whereas angle er-ror was greater for SLM (17.76 ± 11.29°) than for casting (9.56 ± 8.88°, P < 0.001). The support-facing wall consistently showed reduced accuracy: in casting, height error in-creased on the support side (P = 0.001); in SLM, both height and angle errors increased on the support side (both P < 0.001). Across conditions, static friction exceeded dynamic friction (all P < 0.001). With steel ligation, friction was higher for casting than SLM (median static 6.00 N vs 4.35 N, P = 0.007; median dynamic 5.03 N vs 3.83 N, P = 0.011). With elastomeric ligation, the ranking reversed, with higher friction for SLM (median static 2.95 N vs 2.05 N, P < 0.001; median dynamic 2.54 N vs 2.03 N, P = 0.003). In this standardized local in vitro model, findings suggest a surface-dependent reduction in accuracy at the support-facing wall and a fabrication-by-ligation interaction that may alter the frictional ranking between steel and elastomeric ligations. Cast brackets showed more consistent full-wire seating, whereas SLM brackets may benefit from calibrated design offsets and targeted finishing to limit undersized or tapered slots; validation beyond this setup is needed.

Scientific ReportsVol. 16(1)
Van Lang University (VN), Phenikaa University (VN)
Openalex Percentile: Top 94%
Orthodontics and Dentofacial Orthopedics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.