A Robust Multistep Digestion Method for Microplastics Detection in Human Tissue by MicroRaman Analysis

The presence of microplastics (MPs) in human tissues has raised growing concerns, necessitating robust protocols for their reliable extraction and analysis. This study systematically evaluated and optimized digestion protocols to efficiently process a variety of human tissues-placenta, lung, kidney, adipose tissue, muscle, spleen, liver, thyroid, and brain-while preserving the integrity of MP particles. Initial assessments employing single-reagent protocols such as nitric acid (HNO<sub>3</sub>), proteinase K enzymatic digestion, and Fenton oxidative digestion demonstrated limited effectiveness, due to incomplete tissue breakdown or formation of turbid digestates that hindered filtration. Building upon these results, combined digestion approaches were investigated to improve organic matter removal and facilitate filtration through fine pore-size filters (0.2 μm). The optimized 3-day protocol included an initial oxidative Fenton digestion followed by enzymatic digestion (proteinase K). The final step involved lipid removal through ethanol addition and sonication, resulting in clear digestates amenable to filtration. This protocol efficiently digested complex tissue matrices, reducing filter clogging at 1-μm size pore and preserving various common MP polymers, including low-density polyethylene (LDPE), polyethylene terephthalate (PET), polytetrafluoroethylene (PTFE), and polyamides (PA6 and PA12). Application of the optimized digestion allowed successful isolation and characterization of MPs using optical microscopy and Raman spectroscopy. The method showed improved reproducibility and reliability over single-reagent protocols, making it suitable for comprehensive MP analysis in human tissues. The application of an efficient and robust protocol for tissue digestion may contribute to advance human exposure assessment and toxicological studies related to MP contamination.

Authors

Institutions

Publication Details

Journal
Drug Testing and Analysis
Published
2026-01-07
DOI
https://doi.org/10.1002/dta.70024
Primary Topic
Microplastics and Plastic Pollution
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Robust Multistep Digestion Method for Microplastics Detection in Human Tissue by MicroRaman Analysis

Rossella Barone, Paolo Fais, Michele Pozzebon, Lucio Litti et al.
Drug Testing and Analysis
Microplastics and Plastic Pollution
article

A Robust Multistep Digestion Method for Microplastics Detection in Human Tissue by MicroRaman Analysis

Rossella Barone, Paolo Fais, Michele Pozzebon, Lucio Litti, Jennifer Paola Pascali, Antonio Ragusa, Arianna Giorgetti, Alberto Fornasari
article en

Abstract

The presence of microplastics (MPs) in human tissues has raised growing concerns, necessitating robust protocols for their reliable extraction and analysis. This study systematically evaluated and optimized digestion protocols to efficiently process a variety of human tissues-placenta, lung, kidney, adipose tissue, muscle, spleen, liver, thyroid, and brain-while preserving the integrity of MP particles. Initial assessments employing single-reagent protocols such as nitric acid (HNO<sub>3</sub>), proteinase K enzymatic digestion, and Fenton oxidative digestion demonstrated limited effectiveness, due to incomplete tissue breakdown or formation of turbid digestates that hindered filtration. Building upon these results, combined digestion approaches were investigated to improve organic matter removal and facilitate filtration through fine pore-size filters (0.2 μm). The optimized 3-day protocol included an initial oxidative Fenton digestion followed by enzymatic digestion (proteinase K). The final step involved lipid removal through ethanol addition and sonication, resulting in clear digestates amenable to filtration. This protocol efficiently digested complex tissue matrices, reducing filter clogging at 1-μm size pore and preserving various common MP polymers, including low-density polyethylene (LDPE), polyethylene terephthalate (PET), polytetrafluoroethylene (PTFE), and polyamides (PA6 and PA12). Application of the optimized digestion allowed successful isolation and characterization of MPs using optical microscopy and Raman spectroscopy. The method showed improved reproducibility and reliability over single-reagent protocols, making it suitable for comprehensive MP analysis in human tissues. The application of an efficient and robust protocol for tissue digestion may contribute to advance human exposure assessment and toxicological studies related to MP contamination.

Drug Testing and AnalysisVol. 18(3)
University of Padua (IT), Azienda Unita' Sanitaria Locale Di Modena (IT), Quanta System (Italy) (IT), University of Bologna (IT)
Fondazione del Monte di Bologna e Ravenna
Openalex Percentile: Top 95%
Microplastics and Plastic Pollution
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.