Breakdown voltage fluctuation and channel shift under high-repetition-frequency pulses in a gas gap

The repetitive breakdown voltage and breakdown channel of a 6 mm atmospheric air gap were investigated using repetitive pulses up to 100 kHz. The results show that below 10 kHz, the breakdown voltage and channel basically remain unchanged over time. Above 20 kHz, however, the breakdown voltage fluctuates quasi-periodically in milliseconds: first gradually increasing, then abruptly dropping, and repeating this cycle. Correspondingly, the breakdown channel first gradually shifts outward and then returns to the axis. This phenomenon could not be observed in the previous relatively low-frequency experiments. The maximum breakdown voltage at 20 kHz exceeds that at 10 kHz, which differs from the conventional recovery curve of breakdown voltage obtained by the double-pulse method. Schlieren imaging and numerical simulations demonstrate that at high frequencies, the dynamic process of heated gas following spark extinguishing leads to the low-density region deviating from the axis, which in turn changes the subsequent breakdown channel length and thus the breakdown voltage. The present work advances the understanding of pulse breakdown and gas recovery under higher repetition frequency.

Authors

Institutions

Publication Details

Journal
Applied Physics Letters
Published
2026-01-05
DOI
https://doi.org/10.1063/5.0309731
Primary Topic
Plasma Applications and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Breakdown voltage fluctuation and channel shift under high-repetition-frequency pulses in a gas gap

Z. Liu, Haoyu Guan, X. Zou, Longkun Hong et al.
Applied Physics Letters
Plasma Applications and Diagnostics
article

Breakdown voltage fluctuation and channel shift under high-repetition-frequency pulses in a gas gap

Z. Liu, Haoyu Guan, X. Zou, Longkun Hong, Liyang Zhang
article en

Abstract

The repetitive breakdown voltage and breakdown channel of a 6 mm atmospheric air gap were investigated using repetitive pulses up to 100 kHz. The results show that below 10 kHz, the breakdown voltage and channel basically remain unchanged over time. Above 20 kHz, however, the breakdown voltage fluctuates quasi-periodically in milliseconds: first gradually increasing, then abruptly dropping, and repeating this cycle. Correspondingly, the breakdown channel first gradually shifts outward and then returns to the axis. This phenomenon could not be observed in the previous relatively low-frequency experiments. The maximum breakdown voltage at 20 kHz exceeds that at 10 kHz, which differs from the conventional recovery curve of breakdown voltage obtained by the double-pulse method. Schlieren imaging and numerical simulations demonstrate that at high frequencies, the dynamic process of heated gas following spark extinguishing leads to the low-density region deviating from the axis, which in turn changes the subsequent breakdown channel length and thus the breakdown voltage. The present work advances the understanding of pulse breakdown and gas recovery under higher repetition frequency.

Applied Physics LettersVol. 128(1)
Tsinghua University (CN)
Openalex Percentile: Top 95%
Plasma Applications and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.