Diagnostic Performance of a DOAC Urine Dipstick in Obese Outpatients with Atrial Fibrillation: Comparison with Plasma Concentrations

<b>Background</b>: atrial fibrillation (AF) patients with obesity and high thromboembolic risk need oral anticoagulant therapy. Limited data are available on direct oral anticoagulants (DOACs) in this population, and a point-of-care method has been validated to support rapid clinical decisions and to identify on-off plasma concentration thresholds. <b>Methods</b>: This is a monocentric, cross-sectional diagnostic accuracy study on obese AF outpatients referred to Policlinico Umberto I of Rome. Urinary Dipsticks were assessed with separate pads for factor Xa (FXA-i) and thrombin inhibitor (THR-i) and compared to the reference standard of trough and peak plasma concentrations with chromogenic assays/dTT and prespecified plasma thresholds for each DOAC. Study endpoints were the sensitivity, specificity, positive and negative predictive values (PPV and NPV) of DOACs Dipstick compared to plasma concentrations. Sub-analyses according to obesity severity and type of DOAC were performed. <b>Results</b>: 320 paired plasma and urine samples were available from 160 enrolled patients (mean age 73.2 ± 9.1 years). Compared to trough plasma concentrations, DOACs Dipstick showed a sensitivity of 99.24% (mean, 95% confidence interval, CI 95.82-99.98), specificity of 6.89% (0.85-22.76), PPV 82.80% (81.32-84.18), NPV 66.67% (15.79-95.52). On the other hand, compared to peak plasma concentrations, DOACs Dipstick showed a sensitivity of 97.8% (93.7-99.5), specificity of 0% (0.0-15.4), and PPV of 85.9% (85.6-86.2). Urinary Dipstick showed a sensitivity of 99.10% (95.4-100.0), specificity of 4.70% (0.60-16.20) and a PPV and NPV of 74.50% (73.2-75.8) and 66.70 (15.7-95.6), compared to plasma thresholds > 30 ng/mL of FXA-I and THR-I. Sub-analyses showed similar results between FXA-i and THR-i. <b>Conclusions</b>: The urine point-of-care has high sensitivity, acceptable PPV, but low specificity and NPV in AF obese patients and may be useful only in selected clinical scenarios.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2026-01-07
DOI
https://doi.org/10.3390/jcm15020466
Primary Topic
Atrial Fibrillation Management and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Diagnostic Performance of a DOAC Urine Dipstick in Obese Outpatients with Atrial Fibrillation: Comparison with Plasma Concentrations

G. Bernardini, Erminia Baldacci, Rosaria Mormile, Danilo Menichelli et al.
Journal of Clinical Medicine
Atrial Fibrillation Management and Outcomes
article

Diagnostic Performance of a DOAC Urine Dipstick in Obese Outpatients with Atrial Fibrillation: Comparison with Plasma Concentrations

G. Bernardini, Erminia Baldacci, Rosaria Mormile, Danilo Menichelli, Job Harenberg, Vittoria Cammisotto, Francesco Violi, Pasquale Pignatelli, Prof. Daniele Pastori, Ilaria Maria Palumbo, Arianna Pannunzio, Nicola Porcu, Antonio Chistolini, Valentina Castellani
article en

Abstract

<b>Background</b>: atrial fibrillation (AF) patients with obesity and high thromboembolic risk need oral anticoagulant therapy. Limited data are available on direct oral anticoagulants (DOACs) in this population, and a point-of-care method has been validated to support rapid clinical decisions and to identify on-off plasma concentration thresholds. <b>Methods</b>: This is a monocentric, cross-sectional diagnostic accuracy study on obese AF outpatients referred to Policlinico Umberto I of Rome. Urinary Dipsticks were assessed with separate pads for factor Xa (FXA-i) and thrombin inhibitor (THR-i) and compared to the reference standard of trough and peak plasma concentrations with chromogenic assays/dTT and prespecified plasma thresholds for each DOAC. Study endpoints were the sensitivity, specificity, positive and negative predictive values (PPV and NPV) of DOACs Dipstick compared to plasma concentrations. Sub-analyses according to obesity severity and type of DOAC were performed. <b>Results</b>: 320 paired plasma and urine samples were available from 160 enrolled patients (mean age 73.2 ± 9.1 years). Compared to trough plasma concentrations, DOACs Dipstick showed a sensitivity of 99.24% (mean, 95% confidence interval, CI 95.82-99.98), specificity of 6.89% (0.85-22.76), PPV 82.80% (81.32-84.18), NPV 66.67% (15.79-95.52). On the other hand, compared to peak plasma concentrations, DOACs Dipstick showed a sensitivity of 97.8% (93.7-99.5), specificity of 0% (0.0-15.4), and PPV of 85.9% (85.6-86.2). Urinary Dipstick showed a sensitivity of 99.10% (95.4-100.0), specificity of 4.70% (0.60-16.20) and a PPV and NPV of 74.50% (73.2-75.8) and 66.70 (15.7-95.6), compared to plasma thresholds > 30 ng/mL of FXA-I and THR-I. Sub-analyses showed similar results between FXA-i and THR-i. <b>Conclusions</b>: The urine point-of-care has high sensitivity, acceptable PPV, but low specificity and NPV in AF obese patients and may be useful only in selected clinical scenarios.

Journal of Clinical MedicineVol. 15(2)
Heidelberg University (DE), Policlinico Umberto I (IT), University Hospital Heidelberg (DE), Istituto Neurologico Mediterraneo (IT), Sapienza University of Rome (IT)
Good health and well-being
Openalex Percentile: Top 96%
Atrial Fibrillation Management and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.