Thermodynamic analysis of a dual mixed-refrigerant hydrogen liquefaction process with continuous ortho–para conversion method

Hydrogen liquefaction, essential for storage and transmission in the hydrogen economy, typically consumes one-third of hydrogen’s lower heating value, hindering economic viability. This study analyzes a dual mixed refrigerant (DMR) process for efficient hydrogen liquefaction. The configuration employs two stages,precooling and liquefaction, each utilizing two mixed refrigerant cycles. The precooling stage reduces hydrogen temperature from 25 °C to -190 °C, while the liquefaction stage achieves final cooling to -253 °C. The process implements continuous catalytic ortho–para hydrogen conversion throughout, using equilibrium conditions. Process modeling uses UniSim Design with REFPROP database, incorporating equilibrium hydrogen equations. Parametric analysis identifies optimal operating conditions by varying refrigerant cycle pressures while maintaining 0.5 °C minimum pinch temperatures. Energy performance is evaluated through specific energy consumption (SEC). Exergy analysis reveals heat exchangers and compression systems as primary sources of irreversibility. The study establishes relationships and physical insight between operating parameters and system performance, providing a framework for enhancing DMR processes with continuous ortho–para conversion. • Dual mixed refrigerant analysis for efficient hydrogen liquefaction. • Continuous catalytic ortho–para conversion reduces exergy destructions. • Overall liquefaction SEC of 4.66 kWhkg − 1 . • Physical Phenomena Insights in Dual Mix Refrigerant Liquefaction Process. • Parametric analysis identifies optimal refrigerant pressures and flow rates.

Authors

Institutions

Publication Details

Journal
International Journal of Hydrogen Energy
Published
2026-01-01
DOI
https://doi.org/10.1016/j.ijhydene.2026.153386
Citations
1
Primary Topic
Hybrid Renewable Energy Systems
Type
article
Field-Weighted Citation Impact
9.80
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thermodynamic analysis of a dual mixed-refrigerant hydrogen liquefaction process with continuous ortho–para conversion method

Nicola Andreini, Guido Petri, Adriano Milazzo, Lorenzo Talluri
1 citations
International Journal of Hydrogen Energy
Hybrid Renewable Energy Systems
9.80
article

Thermodynamic analysis of a dual mixed-refrigerant hydrogen liquefaction process with continuous ortho–para conversion method

Nicola Andreini, Guido Petri, Adriano Milazzo, Lorenzo Talluri
article en
1 citations

Abstract

Hydrogen liquefaction, essential for storage and transmission in the hydrogen economy, typically consumes one-third of hydrogen’s lower heating value, hindering economic viability. This study analyzes a dual mixed refrigerant (DMR) process for efficient hydrogen liquefaction. The configuration employs two stages,precooling and liquefaction, each utilizing two mixed refrigerant cycles. The precooling stage reduces hydrogen temperature from 25 °C to -190 °C, while the liquefaction stage achieves final cooling to -253 °C. The process implements continuous catalytic ortho–para hydrogen conversion throughout, using equilibrium conditions. Process modeling uses UniSim Design with REFPROP database, incorporating equilibrium hydrogen equations. Parametric analysis identifies optimal operating conditions by varying refrigerant cycle pressures while maintaining 0.5 °C minimum pinch temperatures. Energy performance is evaluated through specific energy consumption (SEC). Exergy analysis reveals heat exchangers and compression systems as primary sources of irreversibility. The study establishes relationships and physical insight between operating parameters and system performance, providing a framework for enhancing DMR processes with continuous ortho–para conversion. • Dual mixed refrigerant analysis for efficient hydrogen liquefaction. • Continuous catalytic ortho–para conversion reduces exergy destructions. • Overall liquefaction SEC of 4.66 kWhkg − 1 . • Physical Phenomena Insights in Dual Mix Refrigerant Liquefaction Process. • Parametric analysis identifies optimal refrigerant pressures and flow rates.

International Journal of Hydrogen EnergyVol. 205
University of Florence (IT)
Affordable and clean energy
Openalex Percentile: Top 6%
Hybrid Renewable Energy Systems
9.80
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.