Development of Cryogenic X-Ray Detectors Based on Mo/Au TES

Abstract Transition edge sensors (TESs) have emerged as highly sensitive radiation detectors with applications ranging from astrophysics to materials science. In the framework of the Athena X-ray space telescope, we have developed Mo/Au-based TES devices designed to meet the ESA specifications for the X-IFU instrument. The detectors were fabricated using a Mo/Au/Au trilayer process and characterized in a dilution refrigerator using a SQUID readout. From I to V curves and complex impedance measurements, we extracted the electrothermal parameters of the TES, which are consistent with theoretical models. Noise spectra were analyzed to estimate the energy resolution, and an excess noise factor was obtained from the comparison of theoretical and experimental data. A spectral resolution below 4 eV was achieved for 5.9 keV X-rays from a 55 Fe source.

Authors

Institutions

Publication Details

Journal
Journal of Low Temperature Physics
Published
2026-01-07
DOI
https://doi.org/10.1007/s10909-025-03361-9
Citations
1
Primary Topic
Superconducting and THz Device Technology
Type
article
Field-Weighted Citation Impact
23.83

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of Cryogenic X-Ray Detectors Based on Mo/Au TES

Pavel Štrichovanec, L. Fàbrega, Juan Antonio Formigós Bolea, Carlos Pobes et al.
1 citations
Journal of Low Temperature Physics
Superconducting and THz Device Technology
23.83
article

Development of Cryogenic X-Ray Detectors Based on Mo/Au TES

Pavel Štrichovanec, L. Fàbrega, Juan Antonio Formigós Bolea, Carlos Pobes, J. L. García-Palacios, J. I. Rico-Camacho, A. Camón
article en
1 citations

Abstract

Abstract Transition edge sensors (TESs) have emerged as highly sensitive radiation detectors with applications ranging from astrophysics to materials science. In the framework of the Athena X-ray space telescope, we have developed Mo/Au-based TES devices designed to meet the ESA specifications for the X-IFU instrument. The detectors were fabricated using a Mo/Au/Au trilayer process and characterized in a dilution refrigerator using a SQUID readout. From I to V curves and complex impedance measurements, we extracted the electrothermal parameters of the TES, which are consistent with theoretical models. Noise spectra were analyzed to estimate the energy resolution, and an excess noise factor was obtained from the comparison of theoretical and experimental data. A spectral resolution below 4 eV was achieved for 5.9 keV X-rays from a 55 Fe source.

Journal of Low Temperature PhysicsVol. 222(1)
Universidad de Zaragoza (ES), Centro Universitario de la Defensa en San Javier (ES), Instituto de Nanociencia y Materiales de Aragón (ES), Institut de Ciència de Materials de Barcelona (ES)
Ministerio de Ciencia, Innovación y Universidades, Ministerio de Ciencia e Innovación, Agencia Estatal de Investigación
Affordable and clean energy
Openalex Percentile: Top 2%
Superconducting and THz Device Technology
23.83
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.