Scalable 68Ga Cold Kit Radiolabeling: High-Throughput Preparation of [68Ga]Ga-Edotreotide via Aliquoting and Dual Generator Strategy

Abstract The aim of the study was to develop and assess alternative radiolabeling strategies for SOMAKIT-TOC using gallium-68, with the aim of improving cost-efficiency by increasing the number of examinations per cold kit while maintaining radiochemical quality suitable for clinical use. Four protocols were evaluated using triplicate test radiolabelings: (1) the reference method using a single generator and a full kit; (2) dual-generator elution into a full kit; (3) single-generator elution into two sequentially radiolabeled aliquots from one kit; and (4) dual-generator elution into two sequentially radiolabeled aliquots from one kit. Radiochemical purity (RCP) was assessed by radio-thin layer chromatography (rTLC) and radio-high performance liquid chromatography (rHPLC), and radiochemical stability was monitored over 4 hours. Additional quality controls parameters included pH, sterility, and peptide integrity in aliquot solution. Procedures 1 and 3 were further assessed in clinical routine. All protocols yielded radiopharmaceuticals with mean RCP values above 95% by rTLC. Procedure 2 significantly increased the final activity compared with Procedure 1. Procedure 3 enabled doubling the number of examinations per kit while maintaining RCP comparable to the reference method Procedure 4 showed greater variability. Radiolabeled products remained stable over 4 hours as assessed by rTLC, although rHPLC revealed a gradual decrease in purity. In clinical use, Procedure 3 allowed 94 preparations that met diagnostic needs, though 33% had RCP between 80 and 95%. Aliquoting a single cold kit for dual radiolabeling using one generator is feasible and cost-effective, although it is associated with greater RCP variability. Dual-generator strategies yield higher activity but may further compromise RCP. Further optimization is required to improve robustness of off-label protocols while preserving the highest product quality.

Authors

Institutions

Publication Details

Journal
World Journal of Nuclear Medicine
Published
2026-01-05
DOI
https://doi.org/10.1055/s-0045-1814733
Primary Topic
Radiopharmaceutical Chemistry and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Scalable 68Ga Cold Kit Radiolabeling: High-Throughput Preparation of [68Ga]Ga-Edotreotide via Aliquoting and Dual Generator Strategy

Marine Cadet, Léa Rubira, Cyril Fersing, Jade Torchio et al.
World Journal of Nuclear Medicine
Radiopharmaceutical Chemistry and Applications
article

Scalable 68Ga Cold Kit Radiolabeling: High-Throughput Preparation of [68Ga]Ga-Edotreotide via Aliquoting and Dual Generator Strategy

Marine Cadet, Léa Rubira, Cyril Fersing, Jade Torchio, Johanne Vanney, S. Renaud
article en

Abstract

Abstract The aim of the study was to develop and assess alternative radiolabeling strategies for SOMAKIT-TOC using gallium-68, with the aim of improving cost-efficiency by increasing the number of examinations per cold kit while maintaining radiochemical quality suitable for clinical use. Four protocols were evaluated using triplicate test radiolabelings: (1) the reference method using a single generator and a full kit; (2) dual-generator elution into a full kit; (3) single-generator elution into two sequentially radiolabeled aliquots from one kit; and (4) dual-generator elution into two sequentially radiolabeled aliquots from one kit. Radiochemical purity (RCP) was assessed by radio-thin layer chromatography (rTLC) and radio-high performance liquid chromatography (rHPLC), and radiochemical stability was monitored over 4 hours. Additional quality controls parameters included pH, sterility, and peptide integrity in aliquot solution. Procedures 1 and 3 were further assessed in clinical routine. All protocols yielded radiopharmaceuticals with mean RCP values above 95% by rTLC. Procedure 2 significantly increased the final activity compared with Procedure 1. Procedure 3 enabled doubling the number of examinations per kit while maintaining RCP comparable to the reference method Procedure 4 showed greater variability. Radiolabeled products remained stable over 4 hours as assessed by rTLC, although rHPLC revealed a gradual decrease in purity. In clinical use, Procedure 3 allowed 94 preparations that met diagnostic needs, though 33% had RCP between 80 and 95%. Aliquoting a single cold kit for dual radiolabeling using one generator is feasible and cost-effective, although it is associated with greater RCP variability. Dual-generator strategies yield higher activity but may further compromise RCP. Further optimization is required to improve robustness of off-label protocols while preserving the highest product quality.

World Journal of Nuclear Medicine
École Nationale Supérieure de Chimie de Montpellier (FR), Centre National de la Recherche Scientifique (FR), Université de Montpellier (FR), Institut de Recherche en Cancérologie de Montpellier (FR), Institut des Biomolécules Max Mousseron (FR)
Openalex Percentile: Top 96%
Radiopharmaceutical Chemistry and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.