Enabling the recirculation of leukocytes in a high-throughput microphysiological system (MPS) to study immune cell-vascular tissue interactions

Microphysiological systems (MPS) are promising technologies that can enhance the drug development pipeline and fill gaps in identifying medical countermeasures for a variety of public health contexts. The integration of immune cells with MPS is increasingly recognized as a critical element for accurately modeling inflammatory responses in disease, injury, and infection. Specifically, the recruitment of circulating leukocytes to the vascular endothelium is an important first step in the inflammatory cascade. However, developing an MPS that supports physiologically relevant immune cell circulation poses significant biological and engineering challenges due to the delicate, short-lived nature of immune cells and the physical stresses imparted by many pumping systems. Here we present advancements to a previously established high-throughput MPS platform, PREDICT96, to enable recirculation of neutrophil-rich flow within microfluidics-based vascular tissue models. To maintain cells in suspension during recirculation, density adjustments to the culture media were made. Hardware and software controls were integrated to develop a pumping strategy that reduced the peak velocity and acceleration on the recirculating cells, maintaining high viability (90%) and minimal activation of neutrophils for up to 24 hours of continuous recirculation through vascular tissue models. Additionally, an analytical model was developed that mapped pump configuration changes to altered flow characteristics through the system. These technical advancements will enable more accurate modeling of immune cell interactions with tissues in a high-throughput testing platform, which will enhance the understanding of and ability to respond to a range of human health threats.

Authors

Institutions

Publication Details

Journal
Lab on a Chip
Published
2026-01-01
DOI
https://doi.org/10.1039/d5lc01001b
Primary Topic
3D Printing in Biomedical Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enabling the recirculation of leukocytes in a high-throughput microphysiological system (MPS) to study immune cell-vascular tissue interactions

Ryan Dubay, Hesham Azizgolshani, Tyler Gerhardson, Samuel H. Kann et al.
Lab on a Chip
3D Printing in Biomedical Research
article

Enabling the recirculation of leukocytes in a high-throughput microphysiological system (MPS) to study immune cell-vascular tissue interactions

Ryan Dubay, Hesham Azizgolshani, Tyler Gerhardson, Samuel H. Kann, Corin Williams, Nerses J. Haroutunian, Elizabeth Wiellette, Joseph N. Urban, Robert B. Gaibler, Brett C. Isenberg, Anthony Quinnert, Halee Kim
article en

Abstract

Microphysiological systems (MPS) are promising technologies that can enhance the drug development pipeline and fill gaps in identifying medical countermeasures for a variety of public health contexts. The integration of immune cells with MPS is increasingly recognized as a critical element for accurately modeling inflammatory responses in disease, injury, and infection. Specifically, the recruitment of circulating leukocytes to the vascular endothelium is an important first step in the inflammatory cascade. However, developing an MPS that supports physiologically relevant immune cell circulation poses significant biological and engineering challenges due to the delicate, short-lived nature of immune cells and the physical stresses imparted by many pumping systems. Here we present advancements to a previously established high-throughput MPS platform, PREDICT96, to enable recirculation of neutrophil-rich flow within microfluidics-based vascular tissue models. To maintain cells in suspension during recirculation, density adjustments to the culture media were made. Hardware and software controls were integrated to develop a pumping strategy that reduced the peak velocity and acceleration on the recirculating cells, maintaining high viability (90%) and minimal activation of neutrophils for up to 24 hours of continuous recirculation through vascular tissue models. Additionally, an analytical model was developed that mapped pump configuration changes to altered flow characteristics through the system. These technical advancements will enable more accurate modeling of immune cell interactions with tissues in a high-throughput testing platform, which will enhance the understanding of and ability to respond to a range of human health threats.

Lab on a ChipVol. 26(4)
Draper Laboratory (US)
Openalex Percentile: Top 95%
3D Printing in Biomedical Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.