Automated 3D cephalometry: A lightweight V-net for landmark localization on CBCT

Cephalometric analysis is a widely adopted procedure for clinical decision support in orthodontics. It involves manual identification of predefined anatomical landmarks on three-dimensional cone beam CT scans, followed by the computation of linear and angular measurements. To reduce processing time and operator dependency, this study aimed to develop a light-weight deep learning (DL) model capable of automatically localizing 16 anatomically defined landmarks. To ensure model robustness and generalizability, the model was trained on a dataset of 350 manually annotated CBCT scans acquired from various imaging systems, covering a wide range of patient ages and skeletal classifications. The trained model is a V-net, optimized for practical use in clinical workflows. The model achieved a mean localization error of 1.95 ± 1.06 mm, which falls within the clinically acceptable threshold of 2 mm. Moreover, the predicted landmarks were used to calculate cephalometric measurements and compare with manually derived values. The resulting errors was -0.15 ± 0.95° for angular measurements and 0.20 ± 0.28 mm for linear ones, with Bland-Altman analysis demonstrating strong agreement and acceptable variability. These results suggest that automated measurements can reliably replace manual ones. Given the clinical relevance of cephalometric parameters - particularly the ANB angle, which is critical for skeletal classification and orthodontic treatment planning - this model represents a promising clinical decision support tool. Additionally, its low computational complexity enables fast prediction, with mean inference time lower than 32 s per scan, promoting its integration into routine clinical settings due to both technical feasibility and robustness across heterogeneous datasets.

Authors

Institutions

Publication Details

Journal
Computerized Medical Imaging and Graphics
Published
2026-01-06
DOI
https://doi.org/10.1016/j.compmedimag.2026.102700
Primary Topic
Dental Radiography and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Automated 3D cephalometry: A lightweight V-net for landmark localization on CBCT

Gianluca Martino Tartaglia, Giuseppe Baselli, Giuseppe Maurizio Facchi, Marco Serafin et al.
Computerized Medical Imaging and Graphics
Dental Radiography and Imaging
article

Automated 3D cephalometry: A lightweight V-net for landmark localization on CBCT

Gianluca Martino Tartaglia, Giuseppe Baselli, Giuseppe Maurizio Facchi, Marco Serafin, Benedetta Baldini, Marco Bologna, Giulia Rubiu
article en

Abstract

Cephalometric analysis is a widely adopted procedure for clinical decision support in orthodontics. It involves manual identification of predefined anatomical landmarks on three-dimensional cone beam CT scans, followed by the computation of linear and angular measurements. To reduce processing time and operator dependency, this study aimed to develop a light-weight deep learning (DL) model capable of automatically localizing 16 anatomically defined landmarks. To ensure model robustness and generalizability, the model was trained on a dataset of 350 manually annotated CBCT scans acquired from various imaging systems, covering a wide range of patient ages and skeletal classifications. The trained model is a V-net, optimized for practical use in clinical workflows. The model achieved a mean localization error of 1.95 ± 1.06 mm, which falls within the clinically acceptable threshold of 2 mm. Moreover, the predicted landmarks were used to calculate cephalometric measurements and compare with manually derived values. The resulting errors was -0.15 ± 0.95° for angular measurements and 0.20 ± 0.28 mm for linear ones, with Bland-Altman analysis demonstrating strong agreement and acceptable variability. These results suggest that automated measurements can reliably replace manual ones. Given the clinical relevance of cephalometric parameters - particularly the ANB angle, which is critical for skeletal classification and orthodontic treatment planning - this model represents a promising clinical decision support tool. Additionally, its low computational complexity enables fast prediction, with mean inference time lower than 32 s per scan, promoting its integration into routine clinical settings due to both technical feasibility and robustness across heterogeneous datasets.

Computerized Medical Imaging and GraphicsVol. 128
Synlab Czech (Czechia) (CZ), University of Milan (IT), Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico (IT), Giuliani (Italy) (IT), Ospedale San Giuseppe (IT), Politecnico di Milano (IT)
Peace, Justice and strong institutions
Openalex Percentile: Top 95%
Dental Radiography and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.