A Cross-Sectional Comparison of Point-Of-Care A1CNow+ Machine with Laboratory HbA1c in Detecting Diabetes in Urban Communities, South Trinidad, 2019–2020

Abstract Background: About 30% of the Trinidad and Tobago (T and T) population has undiagnosed type 2 diabetes mellitus (T2D). This study aimed to determine if point-of-care (POC) glycated hemoglobin (HbA1c) is sufficiently accurate in a real-world setting to screen and diagnose T2D compared with hospital-based laboratory HbA1c measurements. Materials and Methods: This was a descriptive, cross-sectional study comparing POC capillary results with corresponding venous HbA1c levels measured in a hospital-based laboratory. Eighty eligible participants from urban grocery stores in South Trinidad were enrolled via convenience sampling. Sensitivity, specificity, predictive values, concordance, and mean differences between POC blood HbA1c measurement and laboratory measurement of venous HbA1c levels for diagnosing and screening for diabetes. Concordance was determined by the technique of Lin. The mean difference and limits of agreement were determined using the techniques of Bland and Altman. Results: The concordance between POC and laboratory results was good ( P < 0.001). The mean difference was −0.125% (95% limits of agreement, −0.878 to 0.628%). POC HbA1c measurements of >6.4%, 48 mmol/mol had a specificity of 98.6% and a sensitivity of 77.8% for laboratory measurements of >6.4% for diagnosis of T2D. The POC equivalence value for screening for diabetes or a high risk of developing T2D was ≥5.7%, 39 mmol/mol (sensitivity, 83.3%; specificity, 72.6% for laboratory measurements of ≥6.0%, 42 mmol/mol). Staff were trained in-house to use the POC HbA1c analyzer. Conclusions: POC HbA1c testing has a high predictive value and is a useful component in screening for and diagnosing T2D in remote communities.

Authors

Institutions

Publication Details

Journal
Journal of Diabetology
Published
2026-01-05
DOI
https://doi.org/10.4103/jod.jod_63_25
Primary Topic
Diabetes, Cardiovascular Risks, and Lipoproteins
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Cross-Sectional Comparison of Point-Of-Care A1CNow+ Machine with Laboratory HbA1c in Detecting Diabetes in Urban Communities, South Trinidad, 2019–2020

Kavita Dharamraj, Christopher Chang, Darien Wong, Jeremy Jogie et al.
Journal of Diabetology
Diabetes, Cardiovascular Risks, and Lipoproteins
article

A Cross-Sectional Comparison of Point-Of-Care A1CNow+ Machine with Laboratory HbA1c in Detecting Diabetes in Urban Communities, South Trinidad, 2019–2020

Kavita Dharamraj, Christopher Chang, Darien Wong, Jeremy Jogie, Sarah Rampaul, Dylon Roopchan, Daniella Ramlal
article en

Abstract

Abstract Background: About 30% of the Trinidad and Tobago (T and T) population has undiagnosed type 2 diabetes mellitus (T2D). This study aimed to determine if point-of-care (POC) glycated hemoglobin (HbA1c) is sufficiently accurate in a real-world setting to screen and diagnose T2D compared with hospital-based laboratory HbA1c measurements. Materials and Methods: This was a descriptive, cross-sectional study comparing POC capillary results with corresponding venous HbA1c levels measured in a hospital-based laboratory. Eighty eligible participants from urban grocery stores in South Trinidad were enrolled via convenience sampling. Sensitivity, specificity, predictive values, concordance, and mean differences between POC blood HbA1c measurement and laboratory measurement of venous HbA1c levels for diagnosing and screening for diabetes. Concordance was determined by the technique of Lin. The mean difference and limits of agreement were determined using the techniques of Bland and Altman. Results: The concordance between POC and laboratory results was good ( P < 0.001). The mean difference was −0.125% (95% limits of agreement, −0.878 to 0.628%). POC HbA1c measurements of >6.4%, 48 mmol/mol had a specificity of 98.6% and a sensitivity of 77.8% for laboratory measurements of >6.4% for diagnosis of T2D. The POC equivalence value for screening for diabetes or a high risk of developing T2D was ≥5.7%, 39 mmol/mol (sensitivity, 83.3%; specificity, 72.6% for laboratory measurements of ≥6.0%, 42 mmol/mol). Staff were trained in-house to use the POC HbA1c analyzer. Conclusions: POC HbA1c testing has a high predictive value and is a useful component in screening for and diagnosing T2D in remote communities.

Journal of Diabetology
San Fernando General Hospital (TT)
Sustainable cities and communities
Openalex Percentile: Top 95%
Diabetes, Cardiovascular Risks, and Lipoproteins
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.