Comparative effects of chlorine and UV LED disinfection on drinking water and biofilms, with chlorine causing greater shifts in microbial community composition

Microorganisms in drinking water systems can form biofilms that promote microbial regrowth, and reduce disinfection efficiency, potentially increasing human exposure and health risks. The 16S rRNA gene was sequenced to compare the yearlong impacts of slow-sand filter effluent disinfection by chlorination versus UV light-emitting diodes (LEDs) on bacterial communities in water and biofilm samples at a water treatment plant. Significant differences were observed between sample types (water and biofilm) and sample sources (filter influent, filter effluent, chlorine effluent, and UV LED effluent). Dominant phyla that were observed are commonly found in water treatment systems, including Proteobacteria, Actinobacteria, Bacteroidetes, and Firmicutes, with notable detection of the Polaromonas genus for this rural, mountain setting . Biofilms were significantly different from bulk water in terms of beta diversity and abundance of taxa present. The microbial community in biofilms after chlorination differed significantly from biofilms after filtration and biofilms after UV LED disinfection, while those after filtration did not differ from UV LED disinfection, highlighting the particular significance of chlorine in impacting downstream biofilm microbiomes. This difference in selective pressure due to disinfection was also seen for genera containing potential opportunistic pathogens. Among environmental variables, DOC and precipitation were significantly associated with water sample microbial community structure; and significant relationships were observed with some of the most abundant taxa and/or differentially abundant taxa including Legionella , Escherichia, Shigella , and Pseudomonas . Understanding differences in selective pressure after UV-LED as compared to chlorine disinfection can inform development of disinfection practices to optimize disinfection and minimize human health risks.

Authors

Publication Details

Journal
PLOS Water
Published
2026-01-07
DOI
https://doi.org/10.1371/journal.pwat.0000430
Primary Topic
Legionella and Acanthamoeba research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative effects of chlorine and UV LED disinfection on drinking water and biofilms, with chlorine causing greater shifts in microbial community composition

Natalie M. Hull, Karl G. Linden, Amanda B. Killian, Yijing Liu
PLOS Water
Legionella and Acanthamoeba research
article

Comparative effects of chlorine and UV LED disinfection on drinking water and biofilms, with chlorine causing greater shifts in microbial community composition

Natalie M. Hull, Karl G. Linden, Amanda B. Killian, Yijing Liu
article en

Abstract

Microorganisms in drinking water systems can form biofilms that promote microbial regrowth, and reduce disinfection efficiency, potentially increasing human exposure and health risks. The 16S rRNA gene was sequenced to compare the yearlong impacts of slow-sand filter effluent disinfection by chlorination versus UV light-emitting diodes (LEDs) on bacterial communities in water and biofilm samples at a water treatment plant. Significant differences were observed between sample types (water and biofilm) and sample sources (filter influent, filter effluent, chlorine effluent, and UV LED effluent). Dominant phyla that were observed are commonly found in water treatment systems, including Proteobacteria, Actinobacteria, Bacteroidetes, and Firmicutes, with notable detection of the Polaromonas genus for this rural, mountain setting . Biofilms were significantly different from bulk water in terms of beta diversity and abundance of taxa present. The microbial community in biofilms after chlorination differed significantly from biofilms after filtration and biofilms after UV LED disinfection, while those after filtration did not differ from UV LED disinfection, highlighting the particular significance of chlorine in impacting downstream biofilm microbiomes. This difference in selective pressure due to disinfection was also seen for genera containing potential opportunistic pathogens. Among environmental variables, DOC and precipitation were significantly associated with water sample microbial community structure; and significant relationships were observed with some of the most abundant taxa and/or differentially abundant taxa including Legionella , Escherichia, Shigella , and Pseudomonas . Understanding differences in selective pressure after UV-LED as compared to chlorine disinfection can inform development of disinfection practices to optimize disinfection and minimize human health risks.

PLOS WaterVol. 5(1)
Clean water and sanitation
Openalex Percentile: Top 95%
Legionella and Acanthamoeba research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.