Preparation of activated carbon and β-cyclodextrin modified magnetic nanoparticles for extraction and determination of hippuric acid in urine samples

• An activated carbon and β-cyclodextrin modified magnetic composite (AC/β-CD/Fe 3 O 4 ) was prepared. • The AC/β-CD/Fe 3 O 4 was utilized as an efficient magnetic solid phase extraction adsorbent. • The developed approach was applied to determine hippuric acid in urine matrices. In this study, a novel magnetic adsorbent (AC/β-CD/Fe 3 O 4 ) was prepared for the magnetic solid phase extraction (MSPE) of hippuric acid (HA) from urine. The adsorbent combined the high surface area of activated carbon (AC), the host-guest recognition of β-cyclodextrin (β-CD), and the magnetic responsiveness of Fe 3 O 4 . Under the optimal conditions, the method demonstrated excellent performance for HA detection, with a linearity range of 0.0064-1.0 µg/mL, low limit of detection of 1.9 µg/L, and high precision (RSDs < 5%). Recoveries from spiked urine matrices ranged from 95% to 99%, confirming the method's accuracy and practicality for monitoring HA in real biological matrices.

Authors

Institutions

Publication Details

Journal
Talanta Open
Published
2026-01-06
DOI
https://doi.org/10.1016/j.talo.2026.100613
Citations
1
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
25.69
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Preparation of activated carbon and β-cyclodextrin modified magnetic nanoparticles for extraction and determination of hippuric acid in urine samples

X Y Shan, Yan Jin, Ji Shao, Ling Zhang et al.
1 citations
Talanta Open
Analytical chemistry methods development
25.69
article

Preparation of activated carbon and β-cyclodextrin modified magnetic nanoparticles for extraction and determination of hippuric acid in urine samples

X Y Shan, Yan Jin, Ji Shao, Ling Zhang, Luoxian Yang
article en
1 citations

Abstract

• An activated carbon and β-cyclodextrin modified magnetic composite (AC/β-CD/Fe 3 O 4 ) was prepared. • The AC/β-CD/Fe 3 O 4 was utilized as an efficient magnetic solid phase extraction adsorbent. • The developed approach was applied to determine hippuric acid in urine matrices. In this study, a novel magnetic adsorbent (AC/β-CD/Fe 3 O 4 ) was prepared for the magnetic solid phase extraction (MSPE) of hippuric acid (HA) from urine. The adsorbent combined the high surface area of activated carbon (AC), the host-guest recognition of β-cyclodextrin (β-CD), and the magnetic responsiveness of Fe 3 O 4 . Under the optimal conditions, the method demonstrated excellent performance for HA detection, with a linearity range of 0.0064-1.0 µg/mL, low limit of detection of 1.9 µg/L, and high precision (RSDs < 5%). Recoveries from spiked urine matrices ranged from 95% to 99%, confirming the method's accuracy and practicality for monitoring HA in real biological matrices.

Talanta OpenVol. 13
Hangzhou Center for Disease Control and Prevention (CN)
Openalex Percentile: Top 3%
Analytical chemistry methods development
25.69
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.